Literature DB >> 7637367

Regulation of the aortic valve opening. In vivo dynamic measurement of aortic valve orifice area.

M Higashidate1, K Tamiya, T Beppu, Y Imai.   

Abstract

Aortic valve orifice area was dynamically measured in anesthetized dogs with a new measuring system involving electromagnetic induction. This system permits us real-time measurement of the valve orifice area in beating hearts in situ. The aortic valve was already open before aortic pressure started to increase without detectable antegrade aortic flow. Maximum opening area was achieved while flow was still accelerating at a mean of 20 to 35 msec before peak blood flow. Maximum opening area was affected by not only aortic blood flow but also aortic pressure, which produced aortic root expansion. The aortic valve orifice area's decreasing curve (corresponding to valve closure) was composed of two phases: the initial decrease and late decrease. The initial decrease in aortic valve orifice area was slower (4.1 cm2/sec) than the late decrease (28.5 cm2/sec). Aortic valve orifice area was reduced from maximum to 40% of maximum (in a triangular open position) during the initial slow closing. These measurements showed that (1) initial slow closure of the aortic valve is evoked by leaflet tension which is produced by the aortic root expansion (the leaflet tension tended to make the shape of the aortic orifice triangular) and (2) late rapid closure is induced by backflow of blood into the sinus of Valsalva. Thus, cusp expansion owing to intraaortic pressure plays an important role in the opening and closing of the aortic valve and aortic blood flow.

Entities:  

Mesh:

Year:  1995        PMID: 7637367     DOI: 10.1016/S0022-5223(95)70246-6

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  10 in total

1.  Hemodynamics of the aortic valve and root: implications for surgery.

Authors:  Ruggero De Paulis; Andrea Salica; Giuseppe Pisani; Umberto Morbiducci; Luca Weltert; Daniele Maselli
Journal:  Ann Cardiothorac Surg       Date:  2013-01

2.  Impact of systemic hypertension on the assessment of aortic stenosis.

Authors:  L Kadem; J G Dumesnil; R Rieu; L-G Durand; D Garcia; P Pibarot
Journal:  Heart       Date:  2005-03       Impact factor: 5.994

3.  The effect of aortic wall and aortic leaflet stiffening on coronary hemodynamic: a fluid-structure interaction study.

Authors:  S Nobari; R Mongrain; R Leask; R Cartier
Journal:  Med Biol Eng Comput       Date:  2013-04-03       Impact factor: 2.602

4.  Impact of afterload on the assessment of severity of aortic stenosis.

Authors:  Sung-A Chang; Hyung-Kwan Kim; Dae-Won Sohn
Journal:  J Cardiovasc Ultrasound       Date:  2012-06-25

5.  Aortic valve opening and closure: the clover dynamics.

Authors:  Emmanuel Lansac; Hou-Sen Lim; Yu Shomura; Khee Hiang Lim; Nolan T Rice; Isabelle Di Centa; Pouya Youssefi; Wolfgang Goetz; Carlos M G Duran
Journal:  Ann Cardiothorac Surg       Date:  2019-05

6.  Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography.

Authors:  Linda M de Heer; Ricardo P J Budde; Willem P Th M Mali; Alexander M de Vos; Lex A van Herwerden; Jolanda Kluin
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-27       Impact factor: 2.357

7.  Visualization of Human Aortic Valve Dynamics Using Magnetic Resonance Imaging with Sub-Millisecond Temporal Resolution.

Authors:  Zheng Zhong; Kaibao Sun; Guangyu Dan; Qingfei Luo; Afshin Farzaneh-Far; Meryem Muge Karaman; Xiaohong Joe Zhou
Journal:  J Magn Reson Imaging       Date:  2021-03-24       Impact factor: 5.119

8.  Inadequacy of Augmentation Index for Monitoring Arterial Stiffness: Comparison with Arterial Compliance and Other Hemodynamic Variables.

Authors:  Mehmet Kaya; Vignesh Balasubramanian; John K-J Li
Journal:  Cardiovasc Eng Technol       Date:  2022-01-31       Impact factor: 2.305

9.  Optimal phase analysis of electrocardiogram-gated computed tomography angiography in patients with Stanford type A acute aortic dissection.

Authors:  Kenji Nishida; Yuki Yokoi; Ayumi Yamada; Nobuhiro Takaya; Ken Yamagiwa; Shuichi Kawada; Koichi Mori; Susumu Manabe; Eiichiro Kanda; Tomoyuki Fujioka; Mitsuhiro Kishino; Ukihide Tateishi
Journal:  Eur J Radiol Open       Date:  2020-12-09

10.  Ex vivo evaluation of the Ozaki procedure in comparison with the native aortic valve and prosthetic valves.

Authors:  Hiroyuki Saisho; Michael Scharfschwerdt; Tim Schaller; Najla Sadat; Anas Aboud; Stephan Ensminger; Buntaro Fujita
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-08-03
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.