Quality assurance for gamma knife stereotactic radiosurgery.

A H Maitz1, A Wu, L D Lunsford, J C Flickinger, D Kondziolka, W D Bloomer.   

Abstract

PURPOSE: This quality assurance program is designed for stereotactic radiosurgical units, gamma knife, to check and maintain the unit to preclude accidents and comply with current regulations.
MATERIALS AND METHODS: Over 58 stereotactic radiosurgical units using 201 focused 60Co beams have been installed in the last 7 years and are in use at hospitals throughout the world, with at least 11 additional units being prepared to come on-line in the next year. This system has been in use at the University of Pittsburgh Medical Center (UPMC) for 7 years. A comprehensive quality assurance program has been developed. It includes the physics and dosimetry parameters and safety checks required by regulatory agencies. The program, based on over 7 years of experience in measurements, and used during the treatment of over 1500 patients, is separated into three aspects, namely physics, dosimetry, and safety. The UPMC program hopefully will indicate out-of-tolerance problems. Some quality assurance items are checked on a daily basis prior to patient treatment, while other aspects are checked on a weekly, monthly, and/or annual basis. A complete list of items with their respective time tables and tolerances is provided.
RESULTS: Although experience shows very small margins of error, larger values were chosen to account for variations in equipment and techniques.
CONCLUSIONS: Items included in this quality assurance program should indicate and/or preclude problems encountered in the use of this unit.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7635790     DOI: 10.1016/0360-3016(95)00577-L

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  7 in total

1.  The variable ellipsoid modeling technique as a verification method for the treatment planning system of gamma knife radiosurgery.

Authors:  Beong Ik Hur; Byung Kwan Choi; Soon Ki Sung; Won Ho Cho; Seung Heon Cha; Chang Hwa Choi
Journal:  J Korean Neurosurg Soc       Date:  2010-02-28

2.  American College of Radiology (ACR) and American Society for Radiation Oncology (ASTRO) Practice Guideline for the Performance of Stereotactic Radiosurgery (SRS).

Authors:  Steven K Seung; David A Larson; James M Galvin; Minesh P Mehta; Louis Potters; Christopher J Schultz; Santosh V Yajnik; Alan C Hartford; Seth A Rosenthal
Journal:  Am J Clin Oncol       Date:  2013-06       Impact factor: 2.339

3.  Quality assurance of beam accuracy for Leksell Gamma Unit.

Authors:  C Yu; Z Petrovich; G Luxton
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

4.  Development of a PMMA phantom as a practical alternative for quality control of gamma knife® dosimetry.

Authors:  Jae Pil Chung; Young Min Seong; Tae Yeon Kim; Yona Choi; Tae Hoon Kim; Hyun Joon Choi; Chul Hee Min; Hamza Benmakhlouf; Kook Jin Chun; Hyun-Tai Chung
Journal:  Radiat Oncol       Date:  2018-09-14       Impact factor: 3.481

5.  Assessment of the accuracy and stability of frameless gamma knife radiosurgery.

Authors:  Hyun-Tai Chung; Woo-Yoon Park; Tae Hoon Kim; Yong Kyun Kim; Kook Jin Chun
Journal:  J Appl Clin Med Phys       Date:  2018-06-03       Impact factor: 2.102

6.  Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique.

Authors:  Beong Ik Hur; Seong Jin Jin; Gyeong Rip Kim; Jong Hyeok Kwak; Young Ha Kim; Sang Weon Lee; Soon Ki Sung
Journal:  J Korean Neurosurg Soc       Date:  2021-01-01

7.  Filmless quality assurance of a Leksell Gamma Knife® Icon™.

Authors:  Borna Maraghechi; Taeho Kim; Timothy J Mitchell; S Murty Goddu; Joe Dise; James A Kavanaugh; Jacqueline E Zoberi; Sasa Mutic; Nels C Knutson
Journal:  J Appl Clin Med Phys       Date:  2020-12-10       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.