Literature DB >> 7633274

Transcranial Doppler ultrasound in commercial air divers: a field study including cases with right-to-left shunting.

S K Glen1, D Georgiadis, D G Grosset, J D Douglas, K R Lees.   

Abstract

Many cases of decompression illness occur in divers using recommended decompression tables. Doppler ultrasound has been used for over 20 yr and has shown the presence of venous bubbles in asymptomatic divers working well within decompression limits. Previous studies have demonstrated an increased prevalence of patent foramen ovale in divers who have suffered neurologic decompression illness. It has been postulated that right-to-left shunting through a patent foramen ovale could allow arterialization of these bubbles, causing symptoms and signs of acute decompression illness and possibly chronic subclinical neurologic impairment. We set out to determine the incidence of bubbles in the cerebral circulation of commercial divers decompressing from air dives. Using transcranial Doppler ultrasound (TCD), the middle cerebral arteries of 17 divers were monitored after surfacing from depths ranging between 3 and 50 m. Peripheral contrast injection with simultaneous transthoracic echocardiography and TCD was used to screen for right-to-left shunting. Right-to-left shunting was detected in four divers by TCD (one at rest, two after a Valsalva maneuver, and one only after coughing); however, echocardiography was positive in only one of these subjects after a Valsalva maneuver (TCD was positive at rest in this subject). Seventy-three TCD recordings were performed in four settings: 41 after underwater decompression, 18 after surface decompression, 10 in the interval between surfacing and entering the decompression chamber, and 4 after a chamber dive. Twenty-three of these recordings were in four subjects with right-to-left shunting; no bubbles were detected in any of these recordings.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7633274

Source DB:  PubMed          Journal:  Undersea Hyperb Med        ISSN: 1066-2936            Impact factor:   0.698


  6 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

5.  General practice research.

Authors:  J D Douglas
Journal:  Br J Gen Pract       Date:  1996-07       Impact factor: 5.386

6.  Detection of microemboli by transcranial Doppler ultrasound.

Authors:  D G Grosset; D Georgiadis; A W Kelman; P Cowburn; S Stirling; K R Lees; A Faichney; A Mallinson; R Quin; I Bone; L Pettigrew; E Brodie; T MacKay; D J Wheatley
Journal:  Tex Heart Inst J       Date:  1996
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.