Literature DB >> 7615315

Factors related to success and failure rates at 3-year follow-up in a multicenter study of overdentures supported by Brånemark implants.

J E Hutton1, M R Heath, J Y Chai, J Harnett, T Jemt, R B Johns, S McKenna, D C McNamara, D van Steenberghe, R Taylor.   

Abstract

An international prospective study of Brånemark implants retaining overdentures was conducted at nine clinical centers. One hundred thirty-three subjects were recruited in a 12-month period and provided with 510 implants, 117 of which were in maxillae and 393 were in mandibles. This study reports the 3-year follow-up status of 120 overdentures and 444 implants. There were 11 overdenture failures (9.2%). Maxillary overdenture failure rates (27.6%) were nearly nine times greater than mandibular overdenture failure rates (3.3%). Maxillary overdenture treatment was less successful than previously reported fixed implant-supported restorations. However, their mandibular counterparts had success rates slightly higher than those reported for fixed implant-supported restorations. At 3 years, 150 implants remained submerged and 66 implants had been withdrawn because the subjects discontinued study participation. Eleven mandibular and 29 maxillary implants had failed and had been removed from 21 subjects. Logistic regression with forward model selection indicated that one two-way interaction was significantly related to implant failure. At highest risk were the subjects who possessed dental arches with bone quantity E and bone quality 4. Subjects with one implant failure were likely to have more than one failure. The Generalized Estimating Equation was used to adjust for the cluster effect in this population because multiple implants (2 to 6) were placed and evaluated in each of the 133 subjects.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7615315

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  13 in total

1.  3D finite element analysis to detect stress distribution: spiral family implants.

Authors:  Matteo Danza; Ilaria Zollino; Luigi Paracchini; Guidi Riccardo; Stefano Fanali; Francesco Carinci
Journal:  J Maxillofac Oral Surg       Date:  2010-04-24

Review 2.  Significance of osteoporosis in craniomaxillofacial surgery: a review of the literature.

Authors:  B Hohlweg-Majert; R Schmelzeisen; B M Pfeiffer; E Schneider
Journal:  Osteoporos Int       Date:  2005-07-16       Impact factor: 4.507

3.  Histomorphometric evaluation of implants coated with enamel or dentine derived fluoride-substituted apatite.

Authors:  Mehmet Kürkcü; Mehmet Emre Benlidayi; Serhat Ozsoy; Lütfiye Sevgi Ozyeğin; Faik Nuzhet Oktar; Cem Kurtoğlu
Journal:  J Mater Sci Mater Med       Date:  2007-06-19       Impact factor: 3.896

4.  Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage.

Authors:  Min-Jeong Kim; Sung-Ok Hong
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

Review 5.  Osteoporosis: Its Prosthodontic Considerations - A Review.

Authors:  Vinod Bandela; Bharathi Munagapati; Rajeev K Reddy Karnati; Giridhar Reddy Sirupa Venkata; Simhachalam Reddy Nidudhur
Journal:  J Clin Diagn Res       Date:  2015-12-01

6.  Three dimensional finite element analysis to detect stress distribution in spiral implants and surrounding bone.

Authors:  Matteo Danza; Annalisa Palmieri; Francesca Farinella; Giorgio Brunelli; Francesco Carinci; Ambra Girardi; Giuseppe Spinelli
Journal:  Dent Res J (Isfahan)       Date:  2009

7.  2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

Authors:  Shrikar R Desai; Rika Singh; I Karthikeyan
Journal:  J Indian Soc Periodontol       Date:  2013-09

8.  Investigation of pathogenic genes in peri-implantitis from implant clustering failure patients: a whole-exome sequencing pilot study.

Authors:  Soohyung Lee; Ji-Young Kim; Jihye Hwang; Sanguk Kim; Jae-Hoon Lee; Dong-Hoo Han
Journal:  PLoS One       Date:  2014-06-12       Impact factor: 3.240

9.  Influence of thread pitch, helix angle, and compactness on micromotion of immediately loaded implants in three types of bone quality: a three-dimensional finite element analysis.

Authors:  Pan Ma; Wei Xiong; Baosheng Tan; Wei Geng; Jiaqiang Liu; Weihong Li; Dehua Li
Journal:  Biomed Res Int       Date:  2014-07-08       Impact factor: 3.411

10.  Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever.

Authors:  Ji-Man Park; Hyun-Joo Kim; Eun-Jin Park; Myung-Rae Kim; Sun-Jong Kim
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.