Literature DB >> 7615283

First clinical results with a real time, electronic imager as an aid to colonoscopy.

B P Saunders1, G D Bell, C B Williams, J S Bladen, A P Anderson.   

Abstract

The early clinical results are described of a real time, electromagnetic imaging system as an aid to colonoscopy. After gaining experience with the use of the system, one experienced endoscopist was randomised to perform consecutive colonoscopies either with (n = 29) or without (n = 26) the imager view. All procedures were recorded on computer disk and replayed for retrospective analysis. Total colonoscopy was achieved in all patients except one (imager view not available). Comparing intubation time and duration of loop formation per patient, there was no significant difference between the two study groups. The number of attempts taken to straighten the colonoscope pre patient, however, was less when the endoscopist was able to see the imager view, p = 0.03. Hand pressure was also more effective when the endoscopist and endoscopy assistant could see the imager display, p = 0.02. Preliminary experience suggests that real time, electronic imaging of colonoscopy is safe, effective, and will improve the accuracy of the procedure.

Entities:  

Mesh:

Year:  1995        PMID: 7615283      PMCID: PMC1382632          DOI: 10.1136/gut.36.6.913

Source DB:  PubMed          Journal:  Gut        ISSN: 0017-5749            Impact factor:   23.059


  9 in total

1.  Competency and the colonoscopist: a learning curve.

Authors:  B R Parry; S M Williams
Journal:  Aust N Z J Surg       Date:  1991-06

2.  Should colonoscopy be the first investigation for colonic disease?

Authors:  D C Lindsay; J G Freeman; I Cobden; C O Record
Journal:  Br Med J (Clin Res Ed)       Date:  1988-01-16

3.  Non-radiological technique for three-dimensional imaging of endoscopes.

Authors:  J S Bladen; A P Anderson; G D Bell; B Rameh; B Evans; D J Heatley
Journal:  Lancet       Date:  1993-03-20       Impact factor: 79.321

4.  Electronic three-dimensional imaging of intestinal endoscopy.

Authors:  C Williams; C Guy; D Gillies; B Saunders
Journal:  Lancet       Date:  1993-03-20       Impact factor: 79.321

5.  Colonoscopy or barium enema as initial investigation of colonic disease.

Authors:  P Durdey; P M Weston; N S Williams
Journal:  Lancet       Date:  1987-09-05       Impact factor: 79.321

6.  Prospective comparison of double contrast barium enema plus flexible sigmoidoscopy v colonoscopy in rectal bleeding: barium enema v colonoscopy in rectal bleeding.

Authors:  E J Irvine; J O'Connor; R A Frost; P Shorvon; S Somers; G W Stevenson; R H Hunt
Journal:  Gut       Date:  1988-09       Impact factor: 23.059

7.  Angiodysplasia--an uncommon cause of colonic bleeding: colonoscopic evaluation of 1,050 patients with rectal bleeding and anaemia.

Authors:  B J Danesh; C Spiliadis; C B Williams; C M Zambartas
Journal:  Int J Colorectal Dis       Date:  1987-11       Impact factor: 2.571

8.  Usefulness of pediatric colonoscopes in adult colonoscopy.

Authors:  L Bat; C B Williams
Journal:  Gastrointest Endosc       Date:  1989 Jul-Aug       Impact factor: 9.427

9.  Colonoscopy findings in symptomatic patients without X-ray evidence of colonic neoplasms.

Authors:  M C Aldridge; A J Sim
Journal:  Lancet       Date:  1986-10-11       Impact factor: 79.321

  9 in total
  13 in total

1.  Training for colonoscopy.

Authors:  T W Balfour
Journal:  J R Soc Med       Date:  2001-04       Impact factor: 5.344

2.  The usefulness of a magnetic endoscope locating device in colonoscopy in daily practice: a prospective case-controlled study.

Authors:  Per Jess; Orhan Bulut; Ahmad Almasi; Peter Waaddegaard
Journal:  Surg Endosc       Date:  2008-10-15       Impact factor: 4.584

3.  Non-radiological technique for 3D imaging of intestinal endoscopes: computerised graphical 3D representation of endoscope and skeleton.

Authors:  R S Rowland; G D Bell
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

4.  Spatial orientation in pathway surgery.

Authors:  Chunman Fan; Dimitra Dodou; Paul Breedveld; Jenny Dankelman
Journal:  Surg Endosc       Date:  2014-12-06       Impact factor: 4.584

5.  A new variable stiffness colonoscope makes colonoscopy easier: a randomised controlled trial.

Authors:  J C Brooker; B P Saunders; S G Shah; C B Williams
Journal:  Gut       Date:  2000-06       Impact factor: 23.059

6.  A preliminary prospective study of the usefulness of a magnetic endoscope locating device during colonoscopy.

Authors:  S Ambardar; T D Arnell; R L Whelan; A Nihalani; K A Forde
Journal:  Surg Endosc       Date:  2005-05-05       Impact factor: 4.584

Review 7.  Alternatives to Incomplete Colonoscopy.

Authors:  Nicolas A Villa; Rahul Pannala; Shabana F Pasha; Jonathan A Leighton
Journal:  Curr Gastroenterol Rep       Date:  2015-11

8.  Colonoscopy aided by magnetic 3D imaging: assessing the routine use of a stiffening sigmoid overtube to speed up the procedure.

Authors:  G D Bell; R S Rowland; M Rutter; M Abu-Sada; S Dogramadzi; C Allen
Journal:  Med Biol Eng Comput       Date:  1999-09       Impact factor: 2.602

9.  Colonoscopy aided by magnetic 3D imaging: is the technique sufficiently sensitive to detect differences between men and women?

Authors:  R S Rowland; G D Bell; S Dogramadzi; C Allen
Journal:  Med Biol Eng Comput       Date:  1999-11       Impact factor: 2.602

Review 10.  Training methods and models for colonoscopic insertion, endoscopic mucosal resection, and endoscopic submucosal dissection.

Authors:  Naohisa Yoshida; Nilesh Fernandopulle; Yutaka Inada; Yuji Naito; Yoshito Itoh
Journal:  Dig Dis Sci       Date:  2014-08-08       Impact factor: 3.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.