Literature DB >> 7609720

Quantitation of SPECT performance: Report of Task Group 4, Nuclear Medicine Committee.

L S Graham, F H Fahey, M T Madsen, A van Aswegen, M V Yester.   

Abstract

A comprehensive performance testing program is an essential ingredient of high-quality single-photon emission computed tomography (SPECT). Many of the procedures previously published are complicated, time consuming, or require a special testing environment. This Task Group developed a protocol for evaluating SPECT imaging systems that was simple, practical, required minimal test equipment, and could be performed in a few hours using processing software available on all nuclear medicine computers. It was designed to test rotational stability of uniformity and sensitivity, tomographic spatial resolution, uniformity and contrast, and the accuracy of attenuation correction. It can be performed in less than three hours and requires only a Co-57 flood source, a line source, and a tomographic cylindrical phantom. The protocol was used 51 times on 42 different cameras (seven vendors) by four different individuals. The results were used to establish acceptable ranges for the measured parameters. The variation between vendors was relatively small and appeared to reflect slight differences in basic camera performance, collimation, and reconstruction software. Individuals can use the tabulated values to evaluate the performance of individual systems.

Mesh:

Substances:

Year:  1995        PMID: 7609720     DOI: 10.1118/1.597605

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  Performance of dedicated emission mammotomography for various breast shapes and sizes.

Authors:  C N Brzymialkiewicz; M P Tornai; R L McKinley; S J Cutler; J E Bowsher
Journal:  Phys Med Biol       Date:  2006-09-19       Impact factor: 3.609

2.  A novel method to evaluate gamma camera rotational uniformity and sensitivity variation.

Authors:  S Cheenu Kappadath; William D Erwin; Richard E Wendt
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

3.  Evaluation of a multicrystal gamma camera and rotating chair for tomographic studies of the heart.

Authors:  M K O'Connor; J Koss; C Caiati; R L Morin; T F Christian; R J Gibbons
Journal:  J Nucl Cardiol       Date:  1996 Jul-Aug       Impact factor: 5.952

Review 4.  Understanding Fourier space and filter selection.

Authors:  I G Zubal; G Wisniewski
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

Review 5.  Routine quality control of clinical nuclear medicine instrumentation: a brief review.

Authors:  Pat Zanzonico
Journal:  J Nucl Med       Date:  2008-07       Impact factor: 10.057

6.  Reduction in camera-specific variability in [(123)I]FP-CIT SPECT outcome measures by image reconstruction optimized for multisite settings: impact on age-dependence of the specific binding ratio in the ENC-DAT database of healthy controls.

Authors:  Ralph Buchert; Andreas Kluge; Livia Tossici-Bolt; John Dickson; Marcus Bronzel; Catharina Lange; Susanne Asenbaum; Jan Booij; L Özlem Atay Kapucu; Claus Svarer; Pierre-Malick Koulibaly; Flavio Nobili; Marco Pagani; Osama Sabri; Terez Sera; Klaus Tatsch; Thierry Vander Borght; Koen Van Laere; Andrea Varrone; Hidehiro Iida
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-01-27       Impact factor: 9.236

7.  Three-dimensional brain phantom containing bone and grey matter structures with a realistic head contour.

Authors:  Hidehiro Iida; Yuki Hori; Kenji Ishida; Etsuko Imabayashi; Hiroshi Matsuda; Masaaki Takahashi; Hirotaka Maruno; Akihide Yamamoto; Kazuhiro Koshino; Junichiro Enmi; Satoshi Iguchi; Tetsuaki Moriguchi; Hidekazu Kawashima; Tsutomu Zeniya
Journal:  Ann Nucl Med       Date:  2012-09-26       Impact factor: 2.668

8.  Effects of voxel size and iterative reconstruction parameters on the spatial resolution of 99mTc SPECT/CT.

Authors:  S Cheenu Kappadath
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

9.  Evaluation of external beam hardening filters on image quality of computed tomography and single photon emission computed tomography/computed tomography.

Authors:  Nivedita Rana; Dinesh Rawat; Madan Parmar; Devinder Kumar Dhawan; Ashok Kumar Bhati; Bhagwant Rai Mittal
Journal:  J Med Phys       Date:  2015 Oct-Dec

10.  Quantitative assessment of rest and acetazolamide CBF using quantitative SPECT reconstruction and sequential administration of (123)I-iodoamphetamine: comparison among data acquired at three institutions.

Authors:  Miho Yamauchi; Etsuko Imabayashi; Hiroshi Matsuda; Jyoji Nakagawara; Masaaki Takahashi; Eku Shimosegawa; Jun Hatazawa; Michiyasu Suzuki; Hideyuki Iwanaga; Kenji Fukuda; Koji Iihara; Hidehiro Iida
Journal:  Ann Nucl Med       Date:  2014-07-08       Impact factor: 2.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.