Literature DB >> 8799252

Evaluation of a multicrystal gamma camera and rotating chair for tomographic studies of the heart.

M K O'Connor1, J Koss, C Caiati, R L Morin, T F Christian, R J Gibbons.   

Abstract

BACKGROUND: This study evaluates the feasibility of performing tomographic studies with a multicrystal gamma camera combined with a rotating chair. METHODS AND
RESULTS: Tomographic acquisitions were performed with a cardiac phantom containing eight defects of different sizes. Defect size was determined from the fraction of counts in the short-axis slices that fell below a fixed threshold value. Image contrast was determined from the ratio of minimum/maximum counts. Images of an American College of Nuclear Physicians cardiac single-photon emission computed tomographic phantom were acquired and the results were compared with those obtained from 194 centers in the United States. For cardiac studies with 201Tl and 99mTc, threshold values of 65% to 70% gave the best correlation (R2 > 0.94) between true and measured defect sizes, although the slope of the regression line was less than 0.95 for both isotopes. Small inferior defects demonstrated poor image contrast, particularly for 99mTc. Of the three defects in the American College of Nuclear Physicians phantom, the two largest were identified in the tomographic images.
CONCLUSIONS: A multicrystal gamma camera system coupled with a rotating chair can be used for tomographic studies of the heart. Image quality is poorer than that seen on conventional single-photon emission computed tomographic systems, particularly for 99mTc.

Mesh:

Year:  1996        PMID: 8799252     DOI: 10.1016/s1071-3581(96)90093-8

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  10 in total

1.  Quantitation of SPECT performance: Report of Task Group 4, Nuclear Medicine Committee.

Authors:  L S Graham; F H Fahey; M T Madsen; A van Aswegen; M V Yester
Journal:  Med Phys       Date:  1995-04       Impact factor: 4.071

2.  Effects of scatter correction on the measurement of infarct size from SPECT cardiac phantom studies.

Authors:  M K O'Connor; C Caiati; T F Christian; R J Gibbons
Journal:  J Nucl Med       Date:  1995-11       Impact factor: 10.057

3.  Feasibility of tomographic 99mTc-hexakis-2-methoxy-2-methylpropyl-isonitrile imaging for the assessment of myocardial area at risk and the effect of treatment in acute myocardial infarction.

Authors:  R J Gibbons; M S Verani; T Behrenbeck; P A Pellikka; M K O'Connor; J J Mahmarian; J H Chesebro; F J Wackers
Journal:  Circulation       Date:  1989-11       Impact factor: 29.690

4.  In vitro validation of a simple tomographic technique for estimation of percentage myocardium at risk using methoxyisobutyl isonitrile technetium 99m (sestamibi).

Authors:  M K O'Connor; T Hammell; R J Gibbons
Journal:  Eur J Nucl Med       Date:  1990

5.  Comparison of reinjection thallium 201 and resting technetium 99m sestamibi tomographic images for the quantification of infarct size after acute myocardial infarction.

Authors:  T F Christian; M K O'Connor; M R Hopfenspirger; R J Gibbons
Journal:  J Nucl Cardiol       Date:  1994 Jan-Feb       Impact factor: 5.952

6.  Mismatch of left ventricular function and infarct size demonstrated by technetium-99m isonitrile imaging after reperfusion therapy for acute myocardial infarction: identification of myocardial stunning and hyperkinesia.

Authors:  T F Christian; T Behrenbeck; P A Pellikka; K C Huber; J H Chesebro; R J Gibbons
Journal:  J Am Coll Cardiol       Date:  1990-12       Impact factor: 24.094

7.  Quantitative myocardial SPECT for infarct sizing: feasibility of a multicenter trial evaluated using a cardiac phantom.

Authors:  M K O'Connor; R J Gibbons; J E Juni; J O'Keefe; A Ali
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

8.  Primary angioplasty in myocardial infarction: assessment of improved myocardial perfusion with technetium-99m isonitrile.

Authors:  T Behrenbeck; P A Pellikka; K C Huber; J F Bresnahan; B J Gersh; R J Gibbons
Journal:  J Am Coll Cardiol       Date:  1991-02       Impact factor: 24.094

9.  Nontraumatic assessment of left ventricular wall motion and regional stroke volume after myocardial infarction.

Authors:  N Schad
Journal:  J Nucl Med       Date:  1977-04       Impact factor: 10.057

10.  Accuracy of diagnosis of coronary artery disease by radionuclide management of left ventricular function during rest and exercise.

Authors:  R H Jones; P McEwan; G E Newman; S Port; S K Rerych; P M Scholz; M T Upton; C A Peter; E H Austin; K H Leong; R J Gibbons; F R Cobb; R E Coleman; D C Sabiston
Journal:  Circulation       Date:  1981-09       Impact factor: 29.690

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.