Literature DB >> 7600174

Active coil isolation in NMR imaging and spectroscopy using PIN diodes and tuned transmission line: a practical approach.

P M Mellor1, D R Checkley.   

Abstract

To improve signal-to-noise (S/N) ratios in biological NMR experiments we have regularly employed close-fitting receiver coils. The poor RF (radio-frequency) homogeneity often exhibited by these coils can be partly overcome by using them with large transmitter coils, provided that good between-coil isolation during the RF transmission and receive periods is achieved. With this in mind, we have used combined PIN diodes and tuned line to isolate transmitter and receiver and to remove transmitter noise. A series of experiments reported here demonstrate (a) distortion-free receiver detuning during free-induction decay, (b) the reduced effect of the receiver coil on the transmitter pulse, (c) an increase in S/N from 71:1 to 158:1, and (d) the effectiveness of transmitter noise isolation. Improvements in S/N, isolation, and image homogeneity illustrate the value of utilizing these devices. Hardware to allow PIN diode switching under computer control is described, utilizing mostly nonmagnetic materials and batteries.

Mesh:

Year:  1995        PMID: 7600174     DOI: 10.1007/BF02426398

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  2 in total

1.  Passive electrical isolation of double coil probes for localized spectroscopy and imaging.

Authors:  P Styles
Journal:  NMR Biomed       Date:  1988-04       Impact factor: 4.044

2.  Design and evaluation of a radio frequency coil for nuclear magnetic resonance imaging of fluorine and protons.

Authors:  P M Joseph; J E Fishman
Journal:  Med Phys       Date:  1985 Nov-Dec       Impact factor: 4.071

  2 in total
  3 in total

1.  Determination of appropriate RF blocking impedance for MRI surface coils and arrays.

Authors:  A Kocharian; P J Rossman; T C Hulshizer; J P Felmlee; S J Riederer
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

2.  Stripline resonator and preamplifier for preclinical magnetic resonance imaging at 4.7 T.

Authors:  Ioannis Lavdas; Hugh C Seton; Charles R Harrington; Claude M Wischik
Journal:  MAGMA       Date:  2011-08-04       Impact factor: 2.310

3.  Diffusion tensor imaging of mouse brain stem and cervical spinal cord.

Authors:  Joong Hee Kim; Justin Haldar; Zhi-Pei Liang; Sheng-Kwei Song
Journal:  J Neurosci Methods       Date:  2008-09-11       Impact factor: 2.390

  3 in total