Literature DB >> 7593063

The effect of the type of cement on early revision of Charnley total hip prostheses. A review of eight thousand five hundred and seventy-nine primary arthroplasties from the Norwegian Arthroplasty Register.

L I Havelin1, B Espehaug, S E Vollset, L B Engesaeter.   

Abstract

We studied the survival of 8579 Charnley prostheses, in 7922 patients, according to the different types of cement that had been used. All of the patients had had a primary total hip replacement for primary coxarthrosis. The mean duration of follow-up was 3.2 years (range, zero to 6.4 years). The data were collected from the national Norwegian Arthroplasty Register. The duration of survival was defined as the time to revision due to aseptic loosening. The Kaplan-Meier estimate of survival at 5.5 years for the 1226 femoral components that had been implanted with low-viscosity cement was 94.1 per cent (95 per cent confidence interval, 92.1 to 96.2 per cent), compared with 98.1 per cent (95 per cent confidence interval, 97.5 to 98.6 per cent) for the 6589 components that had been implanted with high-viscosity cement (p < 0.0001). The remaining 764 femoral components had been implanted with Boneloc cement, which was classified as neither high nor low-viscosity, and these components were considered as a separate group in the analyses. The Boneloc cement had been used for only three years, and the two-year survival rate of these prostheses was 95.5 per cent (p < 0.0001). The cement contained an antibiotic in 2801 (42 per cent of the hips in which the femoral component had been implanted with high-viscosity cement, compared with only thirty (2 per cent) of those in which it had been implanted with low-viscosity cement.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7593063     DOI: 10.2106/00004623-199510000-00009

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  36 in total

1.  The influence of cement viscosity on the early migration of a tapered polished femoral stem.

Authors:  S Glyn-Jones; J Hicks; J Alfaro-Adrian; H S Gill; P McLardy-Smith; D W Murray
Journal:  Int Orthop       Date:  2003-08-12       Impact factor: 3.075

2.  Coordinating retrieval and register studies improves postmarket surveillance.

Authors:  Peter Ellison; Geir Hallan; Paul Johan Høl; Nils Roar Gjerdet; Leif I Havelin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

3.  [Minimal provider volume in total knee replacement : an analysis of the external quality assurance program of North Rhine-Westphalia (QS-NRW)].

Authors:  T Kostuj; U Schulze-Raestrup; M Noack; K Buckup; R Smektala
Journal:  Chirurg       Date:  2011-05       Impact factor: 0.955

4.  Cement-implant interface gaps explain the poor results of CMW3 for femoral stem fixation: A cadaver study of migration, fatigue and mantle morphology.

Authors:  Amos Race; Mark A Miller; Michael T Clarke; Kenneth A Mann
Journal:  Acta Orthop       Date:  2005-10       Impact factor: 3.717

5.  Static shear strength between polished stem and seven commercial acrylic bone cements.

Authors:  Hongyu Zhang; Leigh Brown; Liam Blunt
Journal:  J Mater Sci Mater Med       Date:  2007-07-10       Impact factor: 3.896

6.  Does adding antibiotics to cement reduce the need for early revision in total knee arthroplasty?

Authors:  Eric Bohm; Naisu Zhu; Jing Gu; Nicole de Guia; Cassandra Linton; Tammy Anderson; David Paton; Michael Dunbar
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

7.  Arthroscopic anatomic double bundle anterior cruciate ligament reconstruction: Our experience with follow-up of 4 years.

Authors:  Vivek Machhindra Morey; Hira Lal Nag; Buddhadev Chowdhury; Chaitanya Dev Pannu; Sanjay Meena; Kiran Kumar; Aravindh Palaniswamy
Journal:  J Clin Orthop Trauma       Date:  2015-07-20

8.  Joint responsibility: the need for a national arthroplasty register.

Authors:  D H Sochart; A J Long; M L Porter
Journal:  BMJ       Date:  1996-07-13

9.  Timing of femoral prosthesis insertion during cemented arthroplasty: cement curing and static mechanical strength in an in vivo model.

Authors:  Stephen Hunt; Craig Stone; Shane Seal
Journal:  Can J Surg       Date:  2011-02       Impact factor: 2.089

Review 10.  Patient characteristics affecting the prognosis of total hip and knee joint arthroplasty: a systematic review.

Authors:  Pasqualina L Santaguida; Gillian A Hawker; Pamela L Hudak; Richard Glazier; Nizar N Mahomed; Hans J Kreder; Peter C Coyte; James G Wright
Journal:  Can J Surg       Date:  2008-12       Impact factor: 2.089

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.