Literature DB >> 7588937

Effects of non-linear flow and spatial orientation on technetium-99m hexamethylpropylene amine oxime single-photon emission tomography.

S J Stapleton1, C B Caldwell, L E Ehrlich, C L Leonhardt, S E Black, M J Yaffe.   

Abstract

The effects of two post-acquisition corrections on the visual and quantitative analysis of technetium-99m hexamethylpropylene amine oxime (HMPAO) single-photon emission tomography (SPET) were determined. The corrections were for: (1) the improper spatial orientation of the patient data sets, and (2) the non-linear uptake of HMPAO across the blood-brain barrier. Reorienting the SPET image data sets removed observers' uncertainty in assessment caused by suspected head tilt; however, it increased their uncertainty due to perceived subtle perfusion deficits. Applying the correction to compensate for the decrease in uptake of HMPAO in high-flow regions resulted in an increase in the number of positive assessments. In a study involving 30 patient studies, intra-observer reliability increased from 62% to 83% (average of two observers) after applying both of the corrections, while inter-observer reliability improved from 62% to 81%. Quantitative methods of analysing the images are also affected by the corrections. In an ROI-based classification scheme, the quantitative assessments of more than one-half of the images are affected by the two corrections. These results need to be considered when comparing both quantitative and visual results from different studies in which the corrections may or may not have been applied.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7588937     DOI: 10.1007/BF00808412

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  26 in total

Review 1.  Functional brain SPECT: the emergence of a powerful clinical method.

Authors:  B L Holman; M D Devous
Journal:  J Nucl Med       Date:  1992-10       Impact factor: 10.057

2.  Effect of spatial resolution on SPECT quantification values.

Authors:  A Kojima; M Matsumoto; M Takahashi; Y Hirota; H Yoshida
Journal:  J Nucl Med       Date:  1989-04       Impact factor: 10.057

3.  Accurate three-dimensional registration of CT, PET, and/or MR images of the brain.

Authors:  C A Pelizzari; G T Chen; D R Spelbring; R R Weichselbaum; C T Chen
Journal:  J Comput Assist Tomogr       Date:  1989 Jan-Feb       Impact factor: 1.826

4.  Alzheimer disease: quantitative analysis of I-123-iodoamphetamine SPECT brain imaging.

Authors:  R S Hellman; R S Tikofsky; B D Collier; R G Hoffmann; D W Palmer; S L Glatt; P G Antuono; A T Isitman; R A Papke
Journal:  Radiology       Date:  1989-07       Impact factor: 11.105

5.  The retention of [99mTc]-d,l-HM-PAO in the human brain after intracarotid bolus injection: a kinetic analysis.

Authors:  N A Lassen; A R Andersen; L Friberg; O B Paulson
Journal:  J Cereb Blood Flow Metab       Date:  1988-12       Impact factor: 6.200

6.  Single photon emission computed tomography in AIDS dementia complex.

Authors:  P Pohl; G Vogl; H Fill; H Rössler; R Zangerle; F Gerstenbrand
Journal:  J Nucl Med       Date:  1988-08       Impact factor: 10.057

7.  SPECT with [99mTc]-d,l-hexamethyl-propylene amine oxime (HM-PAO) compared with regional cerebral blood flow measured by PET: effects of linearization.

Authors:  Y Yonekura; S Nishizawa; T Mukai; T Fujita; H Fukuyama; M Ishikawa; H Kikuchi; J Konishi; A R Andersen; N A Lassen
Journal:  J Cereb Blood Flow Metab       Date:  1988-12       Impact factor: 6.200

8.  Quantitative measurements of cerebral blood flow using SPECT and [99mTc]-d,l-HM-PAO compared to xenon-133.

Authors:  A R Andersen; H H Friberg; J F Schmidt; S G Hasselbalch
Journal:  J Cereb Blood Flow Metab       Date:  1988-12       Impact factor: 6.200

9.  Prognostication of recovery following stroke using the comparison of CT and technetium-99m HM-PAO SPECT.

Authors:  J M Mountz; J G Modell; N L Foster; E S DuPree; R J Ackermann; N A Petry; L E Bluemlein; D E Kuhl
Journal:  J Nucl Med       Date:  1990-01       Impact factor: 10.057

10.  Linearization correction of 99mTc-labeled hexamethyl-propylene amine oxime (HM-PAO) image in terms of regional CBF distribution: comparison to C15O2 inhalation steady-state method measured by positron emission tomography.

Authors:  A Inugami; I Kanno; K Uemura; F Shishido; M Murakami; N Tomura; H Fujita; S Higano
Journal:  J Cereb Blood Flow Metab       Date:  1988-12       Impact factor: 6.200

View more