Literature DB >> 3142888

Linearization correction of 99mTc-labeled hexamethyl-propylene amine oxime (HM-PAO) image in terms of regional CBF distribution: comparison to C15O2 inhalation steady-state method measured by positron emission tomography.

A Inugami1, I Kanno, K Uemura, F Shishido, M Murakami, N Tomura, H Fujita, S Higano.   

Abstract

The radioisotope distribution following intravenous injection of 99mTc-labeled hexamethylpropyleneamine oxime (HM-PAO) in the brain was measured by single photon emission computed tomography (SPECT) and corrected for the nonlinearity caused by differences in net extraction. The "linearization" correction was based on a three compartment model, and it required a region of reference to normalize the SPECT image in terms of regional cerebral blood flow distribution. Two different regions of reference, the cerebellum and the whole brain, were tested. The uncorrected and corrected HM-PAO images were compared with cerebral blood flow (CBF) image measured by the C15O2 inhalation steady state method and positron emission tomography (PET). The relationship between uncorrected HM-PAO and PET-CBF showed a correlation coefficient of 0.85 but tended to saturate at high CBF values, whereas it was improved to 0.93 after the "linearization" correction. The whole-brain normalization worked just as well as normalization using the cerebellum. This study constitutes a validation of the "linearization" correction and it suggests that after linearization the HM-PAO image may be scaled to absolute CBF by employing a global hemispheric CBF value as measured by the nontomographic 133Xe clearance method.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3142888     DOI: 10.1038/jcbfm.1988.33

Source DB:  PubMed          Journal:  J Cereb Blood Flow Metab        ISSN: 0271-678X            Impact factor:   6.200


  18 in total

1.  Motor stimulation response by technetium-99m hexamethylpropylene amine oxime split-dose method and single photon emission tomography.

Authors:  P Pantano; V Di Piero; M Ricci; C Fieschi; L Bozzao; G L Lenzi
Journal:  Eur J Nucl Med       Date:  1992

2.  High resolution SPECT, small deep infarcts and diaschisis.

Authors:  J V Bowler; D C Costa; B E Jones; T J Steiner; J P Wade
Journal:  J R Soc Med       Date:  1992-03       Impact factor: 5.344

3.  Demonstration of human motor cortex activation using SPECT.

Authors:  M S George; H A Ring; D C Costa; K Kouris; P J Ell
Journal:  J Neural Transm Gen Sect       Date:  1992

4.  A quantitative approach to technetium-99m hexamethylpropylene amine oxime.

Authors:  H Matsuda; S Tsuji; N Shuke; H Sumiya; N Tonami; K Hisada
Journal:  Eur J Nucl Med       Date:  1992

5.  Clinical application of arterial spin-labeling MR imaging in patients with carotid stenosis: quantitative comparative study with single-photon emission CT.

Authors:  Y Uchihashi; K Hosoda; I Zimine; A Fujita; M Fujii; K Sugimura; E Kohmura
Journal:  AJNR Am J Neuroradiol       Date:  2011-07-14       Impact factor: 3.825

6.  Brain single-photon emission CT studies using 99mTc-HMPAO and 99mTc-ECD early after recanalization by local intraarterial thrombolysis in patients with acute embolic middle cerebral artery occlusion.

Authors:  K Ogasawara; A Ogawa; M Ezura; H Konno; M Suzuki; T Yoshimoto
Journal:  AJNR Am J Neuroradiol       Date:  2001-01       Impact factor: 3.825

7.  Quantification of functional deficit in Alzheimer's disease using a computer-assisted mapping program for 99mTc-HMPAO SPECT.

Authors:  H Karbe; A Kertesz; J Davis; B J Kemp; F S Prato; R L Nicholson
Journal:  Neuroradiology       Date:  1994       Impact factor: 2.804

8.  Regional cerebral blood flow in IDDM patients: effects of diabetes and of recurrent severe hypoglycaemia.

Authors:  K M MacLeod; D A Hepburn; I J Deary; G M Goodwin; N Dougall; K P Ebmeier; B M Frier
Journal:  Diabetologia       Date:  1994-03       Impact factor: 10.122

9.  Evaluation of technetium-99m exametazime stabilised with cobalt chloride as a blood flow tracer in focal cerebral ischaemia.

Authors:  G Gartshore; P Bannan; J Patterson; B Higley; J McCulloch
Journal:  Eur J Nucl Med       Date:  1994-09

10.  Correlation of Asymmetry Indices Measured by Arterial Spin-Labeling MR Imaging and SPECT in Patients with Crossed Cerebellar Diaschisis.

Authors:  K M Kang; C-H Sohn; B S Kim; Y I Kim; S H Choi; T J Yun; J-h Kim; S-W Park; G J Cheon; M H Han
Journal:  AJNR Am J Neuroradiol       Date:  2015-07-30       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.