Literature DB >> 3263980

Quantitative measurements of cerebral blood flow using SPECT and [99mTc]-d,l-HM-PAO compared to xenon-133.

A R Andersen1, H H Friberg, J F Schmidt, S G Hasselbalch.   

Abstract

The uptake and retention in a 2 cm thick brain section was recorded serially by SPECT after i.v. injection of [99mTc]-d,l-HM-PAO (HM-PAO). In 16 patients, the fraction of the administered dose retained by the brain was 5.2 +/- 1%, showing a peak after 40-50s, then decreasing by 10% within the first 10 min and then by only 0.4% per hour. The image contrast was measured in each patient as the regional hemispheric asymmetry difference in percent of the highest value of the two regions. It decreased from 31% at 30-40 s to 25% at 10 min. At 24 h, a value of 19% was reached. Using the images obtained at 10 min after injection, a region to region comparison of the original and corrected HM-PAO images to the xenon-133 regional cerebral blood flow (rCBF) images was performed. Forty-four patients with stroke, epilepsy, dementia, basal ganglia disease, and tumors and control subjects were included in this comparison. The algorithm proposed by Lassen et al. was used to correct the original images for back diffusion of tracer (brain to blood); a good correlation very close to the line of identity between the corrected HM-PAO and xenon-133 data was obtained when using a conversion/clearance ratio of 1.5 and when the noninvolved hemisphere was used as a reference region (r = 0.86, p less than 0.0001). Serial arterial and cerebral venous blood sampling was performed over 10 min following i.v. injection of HM-PAO in six patients. An overall brain retention fraction of 0.37 +/- 0.03 (mean +/- SEM) was calculated from the data. An average CBF of 0.62 +/- 0.12 ml/g/min was determined on the basis of the Fick principle; this compared to a value of 0.59 +/- 0.09 ml/g/min (mean +/- SEM) measured by the xenon-133 inhalation method. The two sets of CBF values correlated linearly with a correlation coefficient of 0.97 (p less than 0.01). Inserting the average CBF value for the hemisphere as measured by the Fick principle into the algorithm described by Lassen et al. yields absolute rCBF values (ml/g/min) directly from the corrected HM-PAO images.(ABSTRACT TRUNCATED AT 400 WORDS)

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3263980     DOI: 10.1038/jcbfm.1988.35

Source DB:  PubMed          Journal:  J Cereb Blood Flow Metab        ISSN: 0271-678X            Impact factor:   6.200


  24 in total

1.  Motor stimulation response by technetium-99m hexamethylpropylene amine oxime split-dose method and single photon emission tomography.

Authors:  P Pantano; V Di Piero; M Ricci; C Fieschi; L Bozzao; G L Lenzi
Journal:  Eur J Nucl Med       Date:  1992

Review 2.  Cerebral blood flow changes in migraine: methods, observations and hypotheses.

Authors:  L Friberg
Journal:  J Neurol       Date:  1991       Impact factor: 4.849

3.  A comparative technetium 99m hexamethylpropylene amine oxime SPET study in different types of dementia.

Authors:  M O Habert; U Spampinato; J L Mas; M L Piketty; M C Bourdel; J de Recondo; P Rondot; S Askienazy
Journal:  Eur J Nucl Med       Date:  1991

4.  Demonstration of human motor cortex activation using SPECT.

Authors:  M S George; H A Ring; D C Costa; K Kouris; P J Ell
Journal:  J Neural Transm Gen Sect       Date:  1992

5.  Evaluating the accuracy of perfusion/metabolism (SPET/PET) ratio in seizure localization.

Authors:  K Buch; H Blumenfeld; S Spencer; E Novotny; I G Zubal
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10-16       Impact factor: 9.236

6.  Required time delay from 99mTc-HMPAO injection to SPECT data acquisition: healthy subjects and patients with rCBF pattern.

Authors:  Gerda Thomsen; Robin de Nijs; Esben Hogh-Rasmussen; Vibe Frokjaer; Claus Svarer; Gitte M Knudsen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-06-10       Impact factor: 9.236

7.  Predictive value of balloon test occlusion of the internal carotid artery.

Authors:  D H Segal; C Sen; J B Bederson; P Catalano; M Sacher; A L Stollman; M Lorberboym
Journal:  Skull Base Surg       Date:  1995

8.  Effects of non-linear flow and spatial orientation on technetium-99m hexamethylpropylene amine oxime single-photon emission tomography.

Authors:  S J Stapleton; C B Caldwell; L E Ehrlich; C L Leonhardt; S E Black; M J Yaffe
Journal:  Eur J Nucl Med       Date:  1995-09

9.  Regional cerebral blood flow in normal pressure hydrocephalus: diagnostic and prognostic aspects.

Authors:  A Larsson; A C Bergh; M Bilting; A Arlig; L Jacobsson; H Stephensen; C Wikkelsö
Journal:  Eur J Nucl Med       Date:  1994-02

10.  Evaluation of technetium-99m exametazime stabilised with cobalt chloride as a blood flow tracer in focal cerebral ischaemia.

Authors:  G Gartshore; P Bannan; J Patterson; B Higley; J McCulloch
Journal:  Eur J Nucl Med       Date:  1994-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.