Literature DB >> 7575966

The effect of glutaraldehyde and microwave disinfection on some properties of acrylic denture resin.

G L Polyzois1, A J Zissis, S A Yannikakis.   

Abstract

This study evaluated the effect of disinfection methods on the dimensional stability, flexural properties, and microhardness of a heat-polymerized denture acrylic resin. A 1- and 12-hour immersion period in 2% alkaline glutaraldehyde, and 3- and 15-minutes exposure to microwaves were employed as disinfection or sterilization procedures. Storage in water for 1 and 12 hours were used as the control. For each procedure 10 specimens were used. The results indicated that the linear changes observed were of no clinical importance. The same conclusion can be drawn for flexural properties and microhardness. The microwave method is a useful alternative to immersion disinfection.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7575966

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  12 in total

1.  Comparative evaluation of color change between two types of acrylic resin and flexible resin after thermo cycling. An in vitro study.

Authors:  Nadira A Hatim; Omar Zeno Al-Tahho
Journal:  J Indian Prosthodont Soc       Date:  2013-05-05

2.  Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study.

Authors:  Jayaprakash Mugur Basavanna; Ravikanth Haridas Jujare; Rana Kalappattil Varghese; Vishwa Deepak Singh; Amit Gaurav
Journal:  J Clin Diagn Res       Date:  2016-03-01

Review 3.  The Effect of Microwave Disinfection on Denture Base Polymers, Liners and Teeth: A Basic Overview.

Authors:  Theodoros Klironomos; Aspasia Katsimpali; Gregory Polyzois
Journal:  Acta Stomatol Croat       Date:  2015-09

4.  The Effect of Repeated Microwaving Disinfection on the Dimensional Stability of Acrylic Dentures.

Authors:  Nick Polychronakis; Stavros Yannikakis; Alcibiades Zissis
Journal:  Acta Stomatol Croat       Date:  2014-12

5.  Preliminary SEM Observations on the Surface of Elastomeric Impression Materials after Immersion or Ozone Disinfection.

Authors:  Nikolas Poulis; Anthony Prombonas; Stavros Yannikakis; Thanasis Karampotsos; Martha-Spyridoula Katsarou; Nikolaos Drakoulis
Journal:  J Clin Diagn Res       Date:  2016-12-01

6.  Effectiveness of Chemical and Microwave Disinfection on Denture Biofilm Fungi and the Influence of Disinfection on Denture Base Adaptation.

Authors:  Mohannad H Al-Saadi
Journal:  J Indian Prosthodont Soc       Date:  2014-02-07

7.  Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases.

Authors:  Rutuja Madhukarrao Nirale; Ram Thombre; Girish Kubasad
Journal:  J Adv Prosthodont       Date:  2012-02-29       Impact factor: 1.904

8.  A comparison of the efficacy of mechanical, chemical, and microwave radiation methods in disinfecting complete dentures.

Authors:  Niloofar Mojarad; Zahra Khalili; Shima Aalaei
Journal:  Dent Res J (Isfahan)       Date:  2017 Mar-Apr

9.  Effect of repeated simulated disinfections by microwave energy on the complete denture base adaptation.

Authors:  Rafael L X Consani; Rose Y Iwasaki; Marcelo F Mesquita; Wilson B Mendes; Simonides Consani
Journal:  Open Dent J       Date:  2008-04-29

10.  Effect of the simulated disinfection by microwave energy on the impact strength of the tooth/acrylic resin adhesion.

Authors:  Rafael L X Consani; Marcelo F Mesquita; Marinaldo H Zampieri; Wilson B Mendes; Simonides Consani
Journal:  Open Dent J       Date:  2008-01-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.