PURPOSE: To evaluate the effect of a reduction in iodine dose by altering volume and/or concentration of contrast material on hepatic contrast enhancement (HCE) values during hepatic helical computed tomography (CT).
MATERIALS AND METHODS: One hundred eleven patients were randomized into four contrast material protocols according to concentration (in milligrams of iodine per milliliter)/volume (in milliliters)/grams of iodine: group 1, ioversol, 320/150/48; group 2, ioversol, 320/100/32; group 3, iohexol, 300/150/45; group 4, ioversol, 300/100/30. Helical CT protocols were identical for the four groups. Time-attenuation curves were constructed; the mean HCE, contrast enhancement index (CEI), and optimal liver scanning interval (OLSI) were calculated; and the results were compared statistically. RESULTS;: Time-attenuation curves, mean HCE, CEI, and OLSI of groups 1 and 3 were significantly superior to those for groups 2 and 4. Decrease in volume from 150 to 100 mliters decreased mean HCE by 27%, CEI by 69%, and OLSI from 80%-100% to 0%-43% at threshold levels of 40-60 HU.
CONCLUSION: Decrease in iodine dose from 45-48 g to 30-32 g significantly decreases all HCE values, which potentially decreases detection of focal hypovascular hepatic lesions.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7568860     DOI: 10.1148/radiology.197.1.7568860

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  3 in total

1.  Pancreatic adenocarcinoma: analysis of the effect of various concentrations of contrast material.

Authors:  Yoshihiko Fukukura; Hiroyuki Hamada; Takuro Kamiyama; Tomohide Yoneyama; Koji Takumi; Masayuki Nakajo
Journal:  Radiat Med       Date:  2008-08-03

2.  Improvement of parenchymal and vascular enhancement using saline flush and power injection for multiple-detector-row abdominal CT.

Authors:  Helmut Schoellnast; Manfred Tillich; Hannes A Deutschmann; Uwe Stessel; Michael J Deutschmann; Gottfried J Schaffler; Renate Schoellnast; Martin M Uggowitzer
Journal:  Eur Radiol       Date:  2003-10-18       Impact factor: 5.315

3.  Selective use of low-osmolality contrast media in computed tomography.

Authors:  Carlos Valls; Eduard Andía; Anna Sánchez; Victor Moreno
Journal:  Eur Radiol       Date:  2001-12-13       Impact factor: 5.315

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.