Literature DB >> 7556298

Estimation of glomerular filtration rate using chromium-51 ethylene diamine tetra-acetic acid and technetium-99m diethylene triamine penta-acetic acid.

A Biggi1, A Viglietti, M C Farinelli, C Bonada, G Camuzzini.   

Abstract

Simultaneous measurements of the clearance rate of chromium-51 ethylene diamine tetra-acetic acid (51Cr-EDTA) and technetium-99m diethylene triamine penta-acetic acid (99mTc-DTPA) were performed in 54 patients with a range of function between 9 and 176 ml/min. Using multiple blood samples the two clearance values correlated well (r = 0.97, SEE 8.6 ml/min) and DTPA clearance was higher by 2.9%. For each radiopharmaceutical the plasma clearance rates obtained using multiple blood samples were compared with those obtained with simplified methods, i.e., the 60-180 min two-sample method of Russell and the mono-exponential method with the Brochner-Mortensen correction. For both radiopharmaceuticals the clearance values correlated well with the Russell method (r = 0.99, SEE = 4.1 ml/min for EDTA; r = 0.99, SEE 4.9 ml/min for DTPA) and the mono-exponential method (r = 0.99, SEE 3.6 ml/min for EDTA; r = 0.99, SEE 3.9 ml/min for DTPA). The mean plasma clearance obtained using multiple blood samples did not differ significantly from that obtained with the Russell method, either in patients with a glomerular filtration rate (GFR) < 30 ml/min or in patients with GFR > or = 30 ml/min. The mean plasma clearance obtained using multiple blood samples differed significantly from that obtained with the mono-exponential method because of the great difference observed in patients with GFR > or = 30 ml/min. It is concluded that the Russell two-sample method after injection of 99mTc-DTPA is accurate enough for routine clinical use.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7556298     DOI: 10.1007/bf00817277

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  13 in total

1.  Estimation of chromium-51 ethylene diamine tetra-acetic acid plasma clearance: a comparative assessment of simplified techniques.

Authors:  G Picciotto; G Cacace; P Cesana; R Mosso; R Ropolo; P G De Filippi
Journal:  Eur J Nucl Med       Date:  1992

2.  Measurement of extracellular volume and renal clearance by a single injection of inulin.

Authors:  H J Ladegaard-Pedersen
Journal:  Scand J Clin Lab Invest       Date:  1972-04       Impact factor: 1.713

3.  Measurement of glomerular filtration rate: single injection plasma clearance method without urine collection.

Authors:  C D Russell; P G Bischoff; F N Kontzen; K L Rowell; M V Yester; L K Lloyd; W N Tauxe; E V Dubovsky
Journal:  J Nucl Med       Date:  1985-11       Impact factor: 10.057

4.  A simple method for the determination of glomerular filtration rate.

Authors:  J Bröchner-Mortensen
Journal:  Scand J Clin Lab Invest       Date:  1972-11       Impact factor: 1.713

5.  Renal inulin clearance versus total plasma clearance of 51Cr-EDTA.

Authors:  J Bröchner-Mortensen; J Giese; N Rossing
Journal:  Scand J Clin Lab Invest       Date:  1969-06       Impact factor: 1.713

6.  Simultaneous measurement of renal clearance and plasma clearance of 99mTc-labelled diethylenetriaminepenta-acetate, 51Cr-labelled ethylenediaminetetra-acetate and inulin in man.

Authors:  M Rehling; M L Møller; B Thamdrup; J O Lund; J Trap-Jensen
Journal:  Clin Sci (Lond)       Date:  1984-05       Impact factor: 6.124

7.  99Tcm-DTPA for the measurement of glomerular filtration rate.

Authors:  A J Hilson; R D Mistry; M N Maisey
Journal:  Br J Radiol       Date:  1976-09       Impact factor: 3.039

8.  Comparison of radionuclide estimation of glomerular filtration rate using technetium 99m diethylenetriaminepentaacetic acid and chromium 51 ethylenediaminetetraacetic acid.

Authors:  J S Fleming; J Wilkinson; R M Oliver; D M Ackery; G M Blake; D G Waller
Journal:  Eur J Nucl Med       Date:  1991

9.  Chromium-51 ethylenediaminetetraacetate for estimation of globerular filtration rate.

Authors:  B D Stacy; G D Thorburn
Journal:  Science       Date:  1966-05-20       Impact factor: 47.728

10.  Comparison of four commercial Tc-99m(Sn)DTPA preparations used for the measurement of glomerular filtration rate: concise communication.

Authors:  J E Carlsen; M L Møller; J O Lund; J Trap-Jensen
Journal:  J Nucl Med       Date:  1980-02       Impact factor: 10.057

View more
  6 in total

1.  Functional immunoassay technology (FIT), a new approach for measuring physiological functions: application of FIT to measure glomerular filtration rate (GFR).

Authors:  Christopher Peter Reinhardt; Michael J Germain; Ernest V Groman; Jeffrey G Mulhern; Rajesh Kumar; Dennis E Vaccaro
Journal:  Am J Physiol Renal Physiol       Date:  2008-09-03

Review 2.  Drug interactions at the renal level. Implications for drug development.

Authors:  P L Bonate; K Reith; S Weir
Journal:  Clin Pharmacokinet       Date:  1998-05       Impact factor: 6.447

3.  Pharmacokinetics of mycophenolate mofetil for autoimmune disease in children.

Authors:  Guido Filler; Miriam Hansen; Claire LeBlanc; Nathalie Lepage; Doris Franke; Ingrid Mai; Janusz Feber
Journal:  Pediatr Nephrol       Date:  2003-04-08       Impact factor: 3.714

4.  Comparison of 51Cr-EDTA and 99mTc-DTPA for glomerular filtration rate measurement.

Authors:  Emmanuelle Vidal-Petiot; Marie Courbebaisse; Marine Livrozet; Gwénaëlle Corrégé; Timofei Rusu; Françoise Montravers; Stéphanie Baron; Léa Dupont; Clara Balouzet; Corinne Smadja; Sébastien Leygnac; Guillaume Pariscoat; Jimmy Rose; François Rouzet; Pascal Houillier; Jean-Philippe Haymann; Martin Flamant
Journal:  J Nephrol       Date:  2021-03-04       Impact factor: 3.902

5.  Comparison of serum creatinine-based estimating equations with gates protocol for predicting glomerular filtration rate in indian population.

Authors:  A V Mulay; S M Gokhale
Journal:  Indian J Nephrol       Date:  2017 Mar-Apr

6.  A Comparison of the Accuracy of Different Single Plasma Sample Methods for Measuring Glomerular Filtration Rate Using 51Cr-EDTA in Children.

Authors:  Sejin Ha; Jong Jin Lee
Journal:  Nucl Med Mol Imaging       Date:  2018-06-28
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.