Literature DB >> 30100942

A Comparison of the Accuracy of Different Single Plasma Sample Methods for Measuring Glomerular Filtration Rate Using 51Cr-EDTA in Children.

Sejin Ha1, Jong Jin Lee1.   

Abstract

PURPOSE: Among the different methods of measuring glomerular filtration rate (GFR) using 51Cr-ethylenediaminetetraacetic acid clearance, the two-plasma-sample method (TPSM) is widely used, and highly accurate. The single-plasma-sample method (SPSM) is occasionally used for simplicity, at the expense of accuracy. Our aims were (1) to investigate the correlation and (2) to compare the accuracy of six known SPSMs in pediatric patients in reference to TPSM.
METHODS: We retrospectively reviewed 122 pediatric cases (65 boys, age 7.3 ± 4.6 years) and analyzed 307 GFR measurements. SPSMs included Groth and Aasted at 120 min, Ham at 120 min, Christensen and Groth at 120 and 240 min, and Jacobsson at 120 and 240 min. Reference GFR (GFRref) was defined using TPSM GFR corrected by the Jodal and Brochner-Mortensen equation. GFRref < 30 mL min-1 1.73 m-2 were excluded. The standard error of the estimate (SEE) and the number of cases with differences > 10% (N10%) were used to evaluate accuracy.
RESULTS: SPSMs generally correlated well with GFRref (r = 0.92~0.99) and were relatively accurate (SEE = 9.21~15.60). Groth and Aasted showed the smallest SEE, while Jacobsson at 240 min showed the smallest N10% for all GFRref ranges. As for the decreased GFRref, Ham was most accurate followed by Jacobsson at 240 min.
CONCLUSIONS: Jacobsson at 240 min provided good accuracy in all GFRref ranges and was well correlated with TPSM. Jacobsson at 240 min might be the most appropriate method to substitute for TPSM in pediatric patients. Ham could be an alternative in patients with impaired renal function.

Entities:  

Keywords:  51Cr-EDTA; Children; Glomerular filtration rate; Single plasma sample method

Year:  2018        PMID: 30100942      PMCID: PMC6066493          DOI: 10.1007/s13139-018-0529-6

Source DB:  PubMed          Journal:  Nucl Med Mol Imaging        ISSN: 1869-3474


  32 in total

1.  K/DOQI clinical practice guidelines for chronic kidney disease: evaluation, classification, and stratification.

Authors: 
Journal:  Am J Kidney Dis       Date:  2002-02       Impact factor: 8.860

2.  A simple method of estimating glomerular filtration rate.

Authors:  W S Watson
Journal:  Eur J Nucl Med       Date:  1992

3.  Monitoring renal function during chemotherapy.

Authors:  Louise B Hartlev; Charlotte R Boeje; Henrik Bluhme; Torben Palshof; Michael Rehling
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-06-15       Impact factor: 9.236

4.  Report of the Radionuclides in Nephrourology Committee on renal clearance.

Authors:  M D Blaufox; M Aurell; B Bubeck; E Fommei; A Piepsz; C Russell; A Taylor; H S Thomsen; D Volterrani
Journal:  J Nucl Med       Date:  1996-11       Impact factor: 10.057

5.  Correction of the slope-intercept method for the measurement of glomerular filtration rate.

Authors:  Glen M Blake; Mark C Barnfield; Maria T Burniston; John S Fleming; Philip S Cosgriff; Musib Siddique
Journal:  Nucl Med Commun       Date:  2014-12       Impact factor: 1.690

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  51Cr-EDTA clearance determined by one plasma sample in children.

Authors:  S Groth; M Aasted
Journal:  Clin Physiol       Date:  1984-02

8.  A simple method for accurate assessment of the glomerular filtration rate in children.

Authors:  J Bröchner-Mortensen; J Haahr; J Christoffersen
Journal:  Scand J Clin Lab Invest       Date:  1974-04       Impact factor: 1.713

9.  Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults.

Authors:  G B Haycock; G J Schwartz; D H Wisotsky
Journal:  J Pediatr       Date:  1978-07       Impact factor: 4.406

10.  Comparison of radionuclide estimation of glomerular filtration rate using technetium 99m diethylenetriaminepentaacetic acid and chromium 51 ethylenediaminetetraacetic acid.

Authors:  J S Fleming; J Wilkinson; R M Oliver; D M Ackery; G M Blake; D G Waller
Journal:  Eur J Nucl Med       Date:  1991
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.