Literature DB >> 7497689

Flat-on-flat, nonconstrained, compression molded polyethylene total knee replacement.

M A Ritter1, R Worland, J Saliski, J V Helphenstine, K L Edmondson, E M Keating, P M Faris, J B Meding.   

Abstract

Flat-on-flat, posterior cruciate ligament-sparing total knee prostheses recently have shown problems of wear, loosening, and multiple design changes. Two thousand one Anatomical Graduated Components total knee arthroplasties with compression molded, nonmodular polyethylene tibial components were done between 1983 and 1991 at 3 institutions. All knees were evaluated clinically and radiographically every 2 to 3 years; 71 knees were seen in followup > 10 years. There were 8 failures secondary to revision (5 tibial failures; 2 secondary to metalosis from patellar polyethylene dissociation; and 3 femoral failures) resulting in a 98% survival rate at 10 years. The tibial design was flat-on-flat with a compression molded polyethylene that the authors believe is the primary reason for its success.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7497689

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  7 in total

Review 1.  Which primary total knee replacement? A review of currently available TKR in the United Kingdom.

Authors:  R Y Liow; D W Murray
Journal:  Ann R Coll Surg Engl       Date:  1997-09       Impact factor: 1.891

Review 2.  Validity of published outcome data concerning Anatomic Graduated Component total knee arthroplasty: a structured literature review including arthroplasty register data.

Authors:  Reinhard Schuh; Gerald Dorninger; Mark Agreiter; Nikolaus Boehler; Gerold Labek
Journal:  Int Orthop       Date:  2011-04-13       Impact factor: 3.075

3.  A retrospective medium- to long-term results of 1500 AGC total knee replacements - An independent centre functional follow up and survivorship.

Authors:  Amit Atrey; Mark C Edmondson; Debra East; Kim Miles; Adrian Butler-Manuel; Nigel Ellens
Journal:  J Orthop       Date:  2014-02-04

4.  Cementless and cemented total knee arthroplasty in patients younger than fifty five years. Which is better?

Authors:  Young-Hoo Kim; Jang-Won Park; Hyung-Mook Lim; Eun-Soo Park
Journal:  Int Orthop       Date:  2014-01-14       Impact factor: 3.075

5.  No difference in terms of radiostereometric analysis between fixed- and mobile-bearing total knee arthroplasty: a randomized, single-blind, controlled trial.

Authors:  M G M Schotanus; P Pilot; B L Kaptein; W F Draijer; P B J Tilman; R Vos; N P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-27       Impact factor: 4.342

6.  Risk factors for revision within 10 years of total knee arthroplasty.

Authors:  Christopher J Dy; Robert G Marx; Kevin J Bozic; Ting Jung Pan; Douglas E Padgett; Stephen Lyman
Journal:  Clin Orthop Relat Res       Date:  2013-12-18       Impact factor: 4.176

7.  Molded, Gamma-radiated, Argon-processed Polyethylene Components of Rotating Hinge Knee Megaprostheses Have a Lower Failure Hazard and Revision Rates Than Air-sterilized, Machined, Ram-extruded Bar Stock Components.

Authors:  Ana C Belzarena; Mohammad A Elalfy; Mohamed A Yakoub; John H Healey
Journal:  Clin Orthop Relat Res       Date:  2021-01-01       Impact factor: 4.755

  7 in total