Literature DB >> 7497656

The efficacy of intramedullary femoral alignment in total knee replacement.

K E Teter1, D Bregman, C W Colwell.   

Abstract

The angle formed between the femoral anatomic axis and the femoral prosthesis was measured on radiographs of 201 total knee arthroplasties. The radiographs were taken on a 51 inch x 14 inch cassette and had to have satisfactory centering and minimal rotation to be included. All total knee arthroplasties had intramedullary femoral alignment. The mean femoral component angle (relative to the femoral anatomic axis) was 6.1 degrees valgus, with a standard deviation of 2 degrees and a range from 2 degrees to 12 degrees valgus. Seventeen knees (8.5%) had a femoral component angle that was < or = 2 degrees valgus or > or = 10 degrees valgus. In 4 knees, medial femoral bowing of the distal third of the femoral shaft caused an excessive valgus cut. In 7 knees, a capacious femoral canal was present that potentially allowed for divergence of the relatively undersized guide rod in the canal. Overall, 8.5% of cuts were believed to be less than ideal. Preoperative radiographs of the entire femur should identify patients in whom errors are more likely and allow for templating the amount of distal femoral bone to be resected. Extra caution is needed in bowed femora and in capacious femoral canals.

Entities:  

Mesh:

Year:  1995        PMID: 7497656

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  19 in total

1.  Computerized tomography scout view for determining distal femoral resection angle in intramedullary instrumentation of total knee arthroplasty.

Authors:  M Murad Uslu; Baris Ozsar; Meric Cirpar; Simay Kara; Fatih Eksioglu; Ozgur Cetik
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-08-22       Impact factor: 4.342

2.  Computer navigation did not improve alignment in a lower-volume total knee practice.

Authors:  W P Yau; K Y Chiu; J L Zuo; W M Tang; T P Ng
Journal:  Clin Orthop Relat Res       Date:  2008-02-08       Impact factor: 4.176

3.  Computer-assisted surgery can reduce blood loss after total knee arthroplasty.

Authors:  Pedro Hinarejos; Mónica Corrales; Antonia Matamalas; Elvira Bisbe; Enric Cáceres
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-12-16       Impact factor: 4.342

4.  Less invasive TKA: extramedullary femoral reference without navigation.

Authors:  Andrea Baldini; Paolo Adravanti
Journal:  Clin Orthop Relat Res       Date:  2008-08-19       Impact factor: 4.176

5.  The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty.

Authors:  Ralf E Rosenberger; Christian Fink; Sebastian Quirbach; Rene Attal; Katja Tecklenburg; Christian Hoser
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-09-20       Impact factor: 4.342

6.  Mechanical axis-derived femoral component rotation in extramedullary total knee arthroplasty: a comparison between femoral transverse axis and transepicondylar axis.

Authors:  Jai-Gon Seo; Young-Wan Moon; Ji-Soon Lim; Se-Jun Park; Sang-Min Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-13       Impact factor: 4.342

7.  Risk factors for tibial implant malpositioning in total knee arthrosplasty-consecutive series of one thousand, four hundred and seventeen cases.

Authors:  Romain Gaillard; Simone Cerciello; Sebastien Lustig; Elvire Servien; Philippe Neyret
Journal:  Int Orthop       Date:  2016-10-13       Impact factor: 3.075

8.  Utility of preoperative distractive stress radiograph for beginners to extent of medial release in total knee arthroplasty.

Authors:  Jae Ang Sim; Ji Hoon Kwak; Sang Hoon Yang; Sung Hoon Moon; Beom Koo Lee; Joon Yub Kim
Journal:  Clin Orthop Surg       Date:  2009-05-30

9.  Varus gonarthrosis predisposes to varus malalignment in TKA.

Authors:  Thomas J Heyse; Ralf Decking; Jack Davis; Friedrich Boettner; Richard S Laskin
Journal:  HSS J       Date:  2009-05-20

10.  Longitudinal shapes of the tibia and femur are unrelated and variable.

Authors:  Stephen M Howell; Kyle Kuznik; Maury L Hull; Robert A Siston
Journal:  Clin Orthop Relat Res       Date:  2009-07-22       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.