Literature DB >> 7495431

An estimation of fatigue life for a carbon fibre/poly ether ether ketone hip joint prosthesis.

M Akay1, N Aslan.   

Abstract

A fracture mechanics approach was applied to estimate the life of a prosthesis injection moulded from short carbon fibre reinforced poly ether ether ketone. Flexural modulus and strength, fracture toughness, fatigue endurance limit, fatigue crack growth rate and threshold stress intensity factor were determined. The dimensions of the test pieces were selected to yield fibre orientation and fibre length distributions similar to those obtained in the prosthesis. Stress levels generated in the prosthesis under different activities were estimated by conducting three-dimensional finite element analysis. It was shown by a fracture mechanics approach that a fatigue failure due to the propagation of an embedded elliptical slit, under these stresses, would be unlikely for a crack length smaller than 1.85 mm. However, the cement would fail under the same conditions, irrespective of the type of the prosthesis employed.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7495431     DOI: 10.1243/PIME_PROC_1995_209_325_02

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  5 in total

1.  The long-term mechanical integrity of non-reinforced PEEK-OPTIMA polymer for demanding spinal applications: experimental and finite-element analysis.

Authors:  Stephen J Ferguson; Judith M A Visser; Anne Polikeit
Journal:  Eur Spine J       Date:  2005-06-07       Impact factor: 3.134

2.  Thermal analysis studies of poly(etheretherketone)/hydroxyapatite biocomposite mixtures.

Authors:  B J Meenan; C McClorey; M Akay
Journal:  J Mater Sci Mater Med       Date:  2000-08       Impact factor: 3.896

Review 3.  PEEK biomaterials in trauma, orthopedic, and spinal implants.

Authors:  Steven M Kurtz; John N Devine
Journal:  Biomaterials       Date:  2007-08-07       Impact factor: 12.479

4.  Carbon/PEEK nails: a case-control study of 22 cases.

Authors:  Federico Sacchetti; Lorenzo Andreani; Michele Palazzuolo; Stephane Cherix; Enrico Bonicoli; Elisabetta Neri; Rodolfo Capanna
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-12-21

5.  A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases.

Authors:  Luigi Tarallo; Raffaele Mugnai; Roberto Adani; Francesco Zambianchi; Fabio Catani
Journal:  J Orthop Traumatol       Date:  2014-07-15
  5 in total