Use of a tantalum-178 generator and a multiwire gamma camera to study the effect of the Mueller maneuver on left ventricular performance: comparison to hemodynamics and single photon emission computed tomography perfusion patterns.

G Gioia1, B Lin, R Katz, A J DiMarino, J D Ogilby, D Cassel, N L DePace, J Heo, A S Iskandrian.   

Abstract

During the Mueller maneuver, there is a decrease in intrathoracic pressure and an increase in transmural left ventricular pressure. The changes in loading conditions cause transient left ventricular dysfunction. This study examined the effects of the Mueller maneuver on left ventricular performance using tantalum (Ta)-178 (half-life 9.3 min) and a multiwire gamma camera. First-pass radionuclide angiograms were obtained at baseline and during Mueller maneuver in 41 patients aged 58 +/- 10 years. In 34 patients, stress single photon emission computed tomography (SPECT) myocardial perfusion imaging with thallium-201 or sestamibi was also performed. Hemodynamic measurements during the Mueller maneuver (n = 10) showed a decrease in systemic pressure (139 +/- 25 mm Hg vs 123 +/- 24 mm Hg, p < 0.001) and pulmonary artery pressure (24 +/- 6 mm Hg vs 14 +/- 12 mm Hg, p = 0.01) and an increase in heart rate (67 +/- 10 bpm vs 75 +/- 14 beats/min, p = 0.001). Among the 34 patients who had perfusion imaging, the left ventricular ejection fraction remained unchanged or increased in 17 patients (group 1) (48% +/- 19% vs 49% +/- 21%, p not significant) and decreased (> or = 5%) in 17 patients (group 2) (55% +/- 13% vs 40% +/- 16%, p = 0.001). The stress SPECT images showed no or only fixed defects in 11 (65%) patients in group 1 and 3 (18%) patients in group 2 (p = 0.02), and reversible defects in 6 (35%) patients in group 1 and 14 (82%) patients in group 2 (p = 0.04).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7484737     DOI: 10.1016/0002-8703(95)90209-0

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  3 in total

1.  Right ventricular pressure-volume loops using simultaneous radionuclide angiography with a multiwire gamma camera and right heart catheterization.

Authors:  Thein Htay; Deval Mehta; Liang Sun; Jeffrey Lacy; Raed Aqel; Jaekyeong Heo; Ami E Iskandrian
Journal:  J Nucl Cardiol       Date:  2005 Jul-Aug       Impact factor: 5.952

2.  Assessment of left ventricular function during upright treadmill exercise with tantalum 178 and multiwire gamma camera.

Authors:  Jaekyeong Heo; Thein Htay; Deval Mehta; Liang Sun; Jeffrey Lacy; Ami E Iskandrian
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

3.  Development and validation of a novel technique for murine first-pass radionuclide angiography with a fast multiwire camera and tantalum 178.

Authors:  J L Lacy; T Nanavaty; D Dai; N Nayak; N Haynes; C Martin
Journal:  J Nucl Cardiol       Date:  2001 Mar-Apr       Impact factor: 5.952