Literature DB >> 16171716

Assessment of left ventricular function during upright treadmill exercise with tantalum 178 and multiwire gamma camera.

Jaekyeong Heo1, Thein Htay, Deval Mehta, Liang Sun, Jeffrey Lacy, Ami E Iskandrian.   

Abstract

BACKGROUND: Prior studies with first-pass radionuclide angiography (RNA) during treadmill exercise used a single-crystal (Anger) or multicrystal gamma camera and technetium 99m tracers. Motion correction, when done, used point sources, which limited correction to only plane movement. METHODS AND
RESULTS: We examined the performance of a multiwire gamma camera (MWGC), generator-produced tantalum 178, and a novel method of motion correction during treadmill exercise testing. We studied 100 patients in whom rest and stress gated tomographic myocardial perfusion images were obtained. Eight patients were excluded because of incomplete data. There were 53 men and 39 women aged 52 +/- 12 years. The resting left ventricular (LV) ejection fraction (EF) was 61% +/- 12% by gated single photon emission computed tomography. Stress myocardial perfusion was normal in 83 patients and abnormal in 9 patients. The resting RNA EF in the upright position was 57% +/- 12% (r = 0.52, P = .0001 vs gated EF). At peak exercise, the EF by MWGC was 60% +/- 26% if uncorrected and 69% +/- 13% after motion correction. Among the 80 patients with normal perfusion and normal resting EF by gated single photon emission computed tomography, a normal response to exercise was seen in 52 (63%) without motion correction and 74 (89%) with motion correction (P < .05).
CONCLUSION: Assessment of LV function is feasible with MWGC. The motion-corrected images significantly improved the results.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16171716     DOI: 10.1016/j.nuclcard.2005.05.021

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  30 in total

Review 1.  The diagnostic and prognostic value of ECG-gated SPECT myocardial perfusion imaging.

Authors:  Vanessa Go; Mehul R Bhatt; Robert C Hendel
Journal:  J Nucl Med       Date:  2004-05       Impact factor: 10.057

2.  Sensitivity, specificity and predictive accuracy of radionuclide cineangiography during exercise in patients with coronary artery disease. Comparison with exercise electrocardiography.

Authors:  J S Borer; K M Kent; S L Bacharach; M V Green; D R Rosing; S F Seides; S E Epstein; G S Johnston
Journal:  Circulation       Date:  1979-09       Impact factor: 29.690

3.  A scintiphotographic method for measuring left ventricular ejection fraction in man without cardiac catheterization.

Authors:  H W Strauss; B L Zaret; P J Hurley; T K Natarajan; B Pitt
Journal:  Am J Cardiol       Date:  1971-11       Impact factor: 2.778

4.  An improved tungsten-178/tantalum-178 generator system for high volume clinical applications.

Authors:  J L Lacy; M E Ball; M S Verani; H B Wiles; J W Babich; A D LeBlanc; M Stabin; L Bolomey; R Roberts
Journal:  J Nucl Med       Date:  1988-09       Impact factor: 10.057

5.  The role of preoperative radionuclide left ventricular ejection fraction for risk assessment in carotid surgery.

Authors:  A Kazmers; M D Cerqueira; R E Zierler
Journal:  Arch Surg       Date:  1988-04

6.  Use of a tantalum-178 generator and a multiwire gamma camera to study the effect of the Mueller maneuver on left ventricular performance: comparison to hemodynamics and single photon emission computed tomography perfusion patterns.

Authors:  G Gioia; B Lin; R Katz; A J DiMarino; J D Ogilby; D Cassel; N L DePace; J Heo; A S Iskandrian
Journal:  Am Heart J       Date:  1995-11       Impact factor: 4.749

7.  A gamma camera for medical applications, using a multiwire proportional counter.

Authors:  J L Lacy; A D LeBlanc; J W Babich; M W Bungo; L A Latson; R M Lewis; L R Poliner; R H Jones; P C Johnson
Journal:  J Nucl Med       Date:  1984-09       Impact factor: 10.057

8.  Prediction of myocardial infarction versus cardiac death by gated myocardial perfusion SPECT: risk stratification by the amount of stress-induced ischemia and the poststress ejection fraction.

Authors:  T Sharir; G Germano; X Kang; H C Lewin; R Miranda; I Cohen; R D Agafitei; J D Friedman; D S Berman
Journal:  J Nucl Med       Date:  2001-06       Impact factor: 10.057

9.  Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: differential stratification for risk of cardiac death and myocardial infarction.

Authors:  R Hachamovitch; D S Berman; L J Shaw; H Kiat; I Cohen; J A Cabico; J Friedman; G A Diamond
Journal:  Circulation       Date:  1998-02-17       Impact factor: 29.690

10.  A theoretical comparison of first-pass and gated equilibrium methods in the measurement of systolic left ventricular function.

Authors:  M V Green; S L Bacharach; J S Borer; R O Bonow
Journal:  J Nucl Med       Date:  1991-09       Impact factor: 10.057

View more
  2 in total

1.  The role of first-pass radionuclide angiography in the era of gated SPECT myocardial perfusion imaging.

Authors:  Rajesh Venkataraman; Jack Heo; Robert C Hendel; John J Mahmarian; Ami E Iskandrian
Journal:  J Nucl Cardiol       Date:  2008-09-07       Impact factor: 5.952

2.  Effect of patient positioning on the evaluation of myocardial perfusion SPECT.

Authors:  Bertalan Kracskó; Sándor Barna; Orsolya Sántha; Anett Kiss; József Varga; Attila Forgács; Ildikó Garai
Journal:  J Nucl Cardiol       Date:  2017-03-30       Impact factor: 5.952

  2 in total