Literature DB >> 11295695

Development and validation of a novel technique for murine first-pass radionuclide angiography with a fast multiwire camera and tantalum 178.

J L Lacy1, T Nanavaty, D Dai, N Nayak, N Haynes, C Martin.   

Abstract

BACKGROUND: The use of genetically altered mice as a model system to study cardiovascular disease has created a need for accurate and quantitative assessment of murine ventricular function. To address this very challenging problem, we have developed a technique of murine first-pass radionuclide angiography using pinhole imaging and the short-lived isotope tantalum 178 (Ta-178) with a high-speed multiwire proportional camera (MPC). METHODS AND RESULTS. An MPC was fitted with a pinhole lens of 2-mm-diameter aperture positioned 15 cm from the camera face. The short-lived isotope Ta-178 (half-life 9.3 minutes) was generated from the tungsten 178 (W-178) (half-life 21.7 days)/Ta-178 generator and concentrated on site to an injection volume of 15 to 20 microL. Mice were imaged in the supine position with the chest wall 3 mm from the camera pinhole aperture, and images were acquired at 160 frames per second after a rapid bolus injection of Ta-178. In the absence of a true gold standard, the technology was validated with measurements in control mice and mice with surgically ligated left anterior descending arteries (LADs). In addition, the effects of pharmacologic intervention with verapamil and with dobutamine were observed. Finally, peak aortic velocity measurements obtained with this technology were compared with those obtained with echocardiographic Doppler ultrasonography, the only available quantitative comparator. There was a significant decrease in the mean left ventricular ejection fraction (LVEF) between normal mice (62% +/- 4.6% [mean +/- SEM], n = 12) and mice with experimentally induced myocardial infarction produced by surgical LAD ligation (22% +/- 2.0%, n = 41; P <.01). The LVEF decreased from 51% +/- 5.8% to 37% +/- 3.5% in a group of normal mice receiving verapamil (P <.05, n = 8) and increased from 34% +/- 2.2% to 43% +/- 2.3% in a group of LAD-ligated mice receiving dobutamine (P <.01, n = 48). Peak camera sensitivity during first pass was 25,000 cps/mCi injected. Intraobserver and interobserver variability of LVEF was studied, yielding r = 0.9639 and 0.9529 and SE of the estimate 2.6% and 3.1%, respectively. Reproducibility in serial studies was excellent (r = 0.92, SE of the estimate 5.18).
CONCLUSIONS: This study demonstrates the development and use of a promising new method that uses the short-lived radioisotope Ta-178 and MPC for noninvasive quantification of murine ventricular function, that produces accurate and highly reproducible results, and that can be applied in multiple serial studies.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11295695     DOI: 10.1067/mnc.2001.112135

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  55 in total

Review 1.  Using genetically modified mice to study apolipoprotein B.

Authors:  S G Young
Journal:  J Atheroscler Thromb       Date:  1996       Impact factor: 4.928

2.  Design features and performance of a PET system for animal research.

Authors:  P D Cutler; S R Cherry; E J Hoffman; W M Digby; M E Phelps
Journal:  J Nucl Med       Date:  1992-04       Impact factor: 10.057

3.  High-resolution cardiac PET in rabbits: imaging and quantitation of myocardial blood flow.

Authors:  K Shimada; K Yoshida; H Tadokoro; S Kitsukawa; A Takami; K Suzuki; S Tanada; Y Masuda
Journal:  J Nucl Med       Date:  1998-12       Impact factor: 10.057

Review 4.  Cardiac transgenic and gene-targeted mice as models of cardiac hypertrophy and failure: a problem of (new) riches.

Authors:  S Izumo; T Shioi
Journal:  J Card Fail       Date:  1998-12       Impact factor: 5.712

5.  An improved tungsten-178/tantalum-178 generator system for high volume clinical applications.

Authors:  J L Lacy; M E Ball; M S Verani; H B Wiles; J W Babich; A D LeBlanc; M Stabin; L Bolomey; R Roberts
Journal:  J Nucl Med       Date:  1988-09       Impact factor: 10.057

6.  Use of a tantalum-178 generator and a multiwire gamma camera to study the effect of the Mueller maneuver on left ventricular performance: comparison to hemodynamics and single photon emission computed tomography perfusion patterns.

Authors:  G Gioia; B Lin; R Katz; A J DiMarino; J D Ogilby; D Cassel; N L DePace; J Heo; A S Iskandrian
Journal:  Am Heart J       Date:  1995-11       Impact factor: 4.749

Review 7.  Wire chambers revisited.

Authors:  R J Ott
Journal:  Eur J Nucl Med       Date:  1993-04

8.  A gamma camera for medical applications, using a multiwire proportional counter.

Authors:  J L Lacy; A D LeBlanc; J W Babich; M W Bungo; L A Latson; R M Lewis; L R Poliner; R H Jones; P C Johnson
Journal:  J Nucl Med       Date:  1984-09       Impact factor: 10.057

9.  Application of positron emission tomography to determine cerebral glucose utilization in conscious infant monkeys.

Authors:  A H Moore; S R Cherry; D B Pollack; D A Hovda; M E Phelps
Journal:  J Neurosci Methods       Date:  1999-05-01       Impact factor: 2.390

Review 10.  MR angiography of abdominal ischemia.

Authors:  K C Li
Journal:  Semin Ultrasound CT MR       Date:  1996-08       Impact factor: 1.875

View more
  3 in total

Review 1.  Measurement of ventricular function with scintigraphic techniques: part I-imaging hardware, radiopharmaceuticals, and first-pass radionuclide angiography.

Authors:  Kim A Williams
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

2.  Microscale impeller pump for recirculating flow in organs-on-chip and microreactors.

Authors:  Sophie R Cook; Hannah B Musgrove; Amy L Throckmorton; Rebecca R Pompano
Journal:  Lab Chip       Date:  2022-02-01       Impact factor: 6.799

Review 3.  The fat-fed apolipoprotein E knockout mouse brachiocephalic artery in the study of atherosclerotic plaque rupture.

Authors:  Andrew R Bond; Christopher L Jackson
Journal:  J Biomed Biotechnol       Date:  2010-11-07
  3 in total