Literature DB >> 7479172

Pacemaker and defibrillator lead entrapment: case studies.

J E Magney1, J A Parsons, D M Flynn, D W Hunter.   

Abstract

Cadavers and cineradiographic analysis have been used to document the effects of the medial subclavicular musculotendinous complex (MSMC) upon lead function. Four cadavers with pacemakers were dissected and photographed to demonstrate the course a lead takes as it passes through the costoclavicular region. One lead had been placed into the cephalic vein. In the other three cadavers, leads placed by currently accepted techniques of subclavian venipuncture were all found to pass through the soft tissues of the subclavicular region before entering the venous system. Cineradiographic results from a patient with a defibrillator, taken before and after replacement of a broken lead, show the effect of clavicular motion on a lead that passes through the MSMC. Furthermore, cineradiography makes it possible to identify the point where the lead entered the vein, and whether or not it escaped being caught up in the soft tissues of the MSMC.

Entities:  

Mesh:

Year:  1995        PMID: 7479172     DOI: 10.1111/j.1540-8159.1995.tb06737.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

1.  Pacemaker lead entrapment syndrome.

Authors:  Kamal Gupta; Rollo P Villareal; Abdi Rasekh; Ali Massumi
Journal:  Tex Heart Inst J       Date:  2003

2.  Pacemaker insertion.

Authors:  Maria Kotsakou; Ioannis Kioumis; George Lazaridis; Georgia Pitsiou; Sofia Lampaki; Antonis Papaiwannou; Anastasia Karavergou; Kosmas Tsakiridis; Nikolaos Katsikogiannis; Ilias Karapantzos; Chrysanthi Karapantzou; Sofia Baka; Ioannis Mpoukovinas; Vasilis Karavasilis; Aggeliki Rapti; Georgia Trakada; Athanasios Zissimopoulos; Konstantinos Zarogoulidis; Paul Zarogoulidis
Journal:  Ann Transl Med       Date:  2015-03

Review 3.  [ICD leads].

Authors:  Carsten W Israel; Mohamed Karim Sheta
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-06

4.  Possible complications of subclavian crush syndrome.

Authors:  S A M Said; C H J M Ticheler; C M Stassen; A Derks; H T Droste
Journal:  Neth Heart J       Date:  2005-03       Impact factor: 2.380

5.  Pneumothorax resulting from subclavian puncture: a complication of permanent pacemaker lead implantation.

Authors:  J C J Res; J A de Priester; A A van Lier; C L J M van Engelen; P N A Bronzwaer; P-H Tan; M Visser
Journal:  Neth Heart J       Date:  2004-03       Impact factor: 2.380

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.