Electrical stimulation with pt electrodes. IV. Factors influencing Pt dissolution in inorganic saline.

J McHardy, L S Robblee, J M Marston, S B Brummer.   

Abstract

Trace analysis has shown that Pt electrodes can suffer appreciable dissolution when used to apply biphasic current pulses of the type used in neural stimulation. The dissolution occurs even under conditions where other irreversible faradaic reactions, e.g., H2O electrolysis, are avoided. In the present study, factors influencing the dissolution of Pt electrodes during biphasic pulsing in neutral inorganic saline have been examined. The findings are consistent with the behaviour of Pt electrodes reported in other inorganic media. In a given test, the quantity of Pt dissolved was found to be a linear function of the aggregate anodic or cathodic charge injected. Therefore, dissolution 'rates' can be conveniently expressed in terms of nanograms of Pt per coulomb injected, e.g., 100 ng C-1. Most of the Pt went into solution as Pt (II) species, so the above rate would correspond approximately to 100 p.p.m. of the anodic charge per pulse. For anodic-first (AF) pulses, charge density was the major factor controlling dissolution, whereas for cathodic-first (CF) pulses, pulse duration had the greater influence. Depending on the polarity (AF or CF), charge density, and duration of the biphasic pulse, the dissolution rate for smooth bead electrodes ranged from 30 to 300 ng C-1. Lower rates were achieved with platinized electrodes but in the absence of organic solutes, it is unlikely that Pt dissolution can be completely suppressed.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7470563     DOI: 10.1016/0142-9612(80)90034-4

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  11 in total

1.  Telemetry system for monitoring anterior cruciate ligament graft forces in vivo.

Authors:  E L McKee; D P Lindsey; M L Hull; S M Howell
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

2.  When are actively balanced biphasic ('Lilly') stimulating pulses necessary in a neurological prosthesis? II. pH changes; noxious products; electrode corrosion; discussion.

Authors:  N D Donaldson; P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1986-01       Impact factor: 2.602

3.  When are actively balanced biphasic ('Lilly') stimulating pulses necessary in a neurological prosthesis? I. Historical background; Pt resting potential; Q studies.

Authors:  N D Donaldson; P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1986-01       Impact factor: 2.602

4.  Comparison of electrical transients and corrosion responses of pulsed MP35N and 316LVM electrodes.

Authors:  L W Riedy; J S Walter
Journal:  Ann Biomed Eng       Date:  1994 Mar-Apr       Impact factor: 3.934

5.  Intraocular retinal prosthesis.

Authors:  M S Humayun
Journal:  Trans Am Ophthalmol Soc       Date:  2001

6.  Electrical neurostimulation with imbalanced waveform mitigates dissolution of platinum electrodes.

Authors:  Doe Kumsa; Eric M Hudak; Fred W Montague; Shawn C Kelley; Darrel F Untereker; Benjamin P Hahn; Chris Condit; Martin Cholette; Hyowon Lee; Dawn Bardot; Pavel Takmakov
Journal:  J Neural Eng       Date:  2016-09-21       Impact factor: 5.379

7.  Scanning electron microscopy of chronically implanted intracortical microelectrode arrays in non-human primates.

Authors:  James C Barrese; Juan Aceros; John P Donoghue
Journal:  J Neural Eng       Date:  2016-01-29       Impact factor: 5.379

8.  Changes in the extracellular microenvironment and osteogenic responses of mesenchymal stem/stromal cells induced by in vitro direct electrical stimulation.

Authors:  Kasama Srirussamee; Ruikang Xue; Sahba Mobini; Nigel J Cassidy; Sarah H Cartmell
Journal:  J Tissue Eng       Date:  2021-02-16       Impact factor: 7.813

9.  Chronic intracochlear electrical stimulation at high charge densities: reducing platinum dissolution.

Authors:  Robert K Shepherd; Paul M Carter; Ya Lang Enke; Alex Thompson; Brianna Flynn; Ella P Trang; Ashley N Dalrymple; James B Fallon
Journal:  J Neural Eng       Date:  2020-10-08       Impact factor: 5.379

10.  Platinum corrosion products from electrode contacts of human cochlear implants induce cell death in cell culture models.

Authors:  Kirsten Wissel; Gudrun Brandes; Nils Pütz; Gian Luigi Angrisani; Jan Thieleke; Thomas Lenarz; Martin Durisin
Journal:  PLoS One       Date:  2018-05-15       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.