Literature DB >> 3959609

When are actively balanced biphasic ('Lilly') stimulating pulses necessary in a neurological prosthesis? I. Historical background; Pt resting potential; Q studies.

N D Donaldson, P E Donaldson.   

Abstract

Mesh:

Substances:

Year:  1986        PMID: 3959609     DOI: 10.1007/bf02441604

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  12 in total

1.  AN ANALYSIS OF ELECTRICAL PROPERTIES OF METAL ELECTRODES.

Authors:  J WEINMAN; J MAHLER
Journal:  Med Electron Biol Eng       Date:  1964-07

2.  Brief, noninjurious electric waveform for stimulation of the brain.

Authors:  J C LILLY; J R HUGHES; E C ALVORD; T W GALKIN
Journal:  Science       Date:  1955-04-01       Impact factor: 47.728

3.  Electrical stimulation with Pt electrodes: II-estimation of maximum surface redox (theoretical non-gassing) limits.

Authors:  S B Brummer; M J Turner
Journal:  IEEE Trans Biomed Eng       Date:  1977-09       Impact factor: 4.538

4.  Electrical stimulation with Pt electrodes: I-a method for determination of "real" electrode areas.

Authors:  S B Brummer; M J Turner
Journal:  IEEE Trans Biomed Eng       Date:  1977-09       Impact factor: 4.538

5.  When are actively balanced biphasic ('Lilly') stimulating pulses necessary in a neurological prosthesis? II. pH changes; noxious products; electrode corrosion; discussion.

Authors:  N D Donaldson; P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1986-01       Impact factor: 2.602

6.  Electrical stimulation with Pt electrodes. V. The effect of protein on Pt dissolution.

Authors:  L S Robblee; J McHardy; J M Marston; S B Brummer
Journal:  Biomaterials       Date:  1980-07       Impact factor: 12.479

7.  Electrical stimulation with pt electrodes. IV. Factors influencing Pt dissolution in inorganic saline.

Authors:  J McHardy; L S Robblee; J M Marston; S B Brummer
Journal:  Biomaterials       Date:  1980-07       Impact factor: 12.479

8.  Electrochemical considerations for safe electrical stimulation of the nervous system with platinum electrodes.

Authors:  S B Brummer; M J Turner
Journal:  IEEE Trans Biomed Eng       Date:  1977-01       Impact factor: 4.538

9.  Linear and nonlinear properties of platinum electrode polarisation. Part 1: frequency dependence at very low frequencies.

Authors:  B Onaral; H P Schwan
Journal:  Med Biol Eng Comput       Date:  1982-05       Impact factor: 2.602

10.  Electrical stimulation with Pt electrodes: Trace analysis for dissolved platinum and other dissolved electrochemical products.

Authors:  S B Brummer; J McHardy; M J Turner
Journal:  Brain Behav Evol       Date:  1977-02       Impact factor: 1.808

View more
  14 in total

1.  Electrical stimulation promotes maturation of cardiomyocytes derived from human embryonic stem cells.

Authors:  Yau-Chi Chan; Sherwin Ting; Yee-Ki Lee; Kwong-Man Ng; Jiao Zhang; Zi Chen; Chung-Wah Siu; Steve K W Oh; Hung-Fat Tse
Journal:  J Cardiovasc Transl Res       Date:  2013-10-01       Impact factor: 4.132

2.  Inductive RF link for an auditory prosthesis.

Authors:  P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1987-05       Impact factor: 2.602

3.  phi Q diagram for a platinum electrode in vivo.

Authors:  M D Craggs; P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1986-05       Impact factor: 2.602

4.  Performance of platinum stimulating electrodes mapped on the limit-voltage plane. Part 2. Corrosion in vitro.

Authors:  N N Donaldson; P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1986-07       Impact factor: 2.602

5.  Performance of platinum stimulating electrodes, mapped on the limit-voltage plane. Part 1. Charge injection in vivo.

Authors:  M D Craggs; N N Donaldson; P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1986-07       Impact factor: 2.602

6.  When are actively balanced biphasic ('Lilly') stimulating pulses necessary in a neurological prosthesis? II. pH changes; noxious products; electrode corrosion; discussion.

Authors:  N D Donaldson; P E Donaldson
Journal:  Med Biol Eng Comput       Date:  1986-01       Impact factor: 2.602

7.  Comparison of electrical transients and corrosion responses of pulsed MP35N and 316LVM electrodes.

Authors:  L W Riedy; J S Walter
Journal:  Ann Biomed Eng       Date:  1994 Mar-Apr       Impact factor: 3.934

8.  Current-Controlled Electrical Point-Source Stimulation of Embryonic Stem Cells.

Authors:  Michael Q Chen; Xiaoyan Xie; Kitchener D Wilson; Ning Sun; Joseph C Wu; Laurent Giovangrandi; Gregory T A Kovacs
Journal:  Cell Mol Bioeng       Date:  2009-12       Impact factor: 2.321

9.  neuroBi: A Highly Configurable Neurostimulator for a Retinal Prosthesis and Other Applications.

Authors:  Kyle D Slater; Nicholas C Sinclair; Timothy S Nelson; Peter J Blamey; Hugh J McDermott
Journal:  IEEE J Transl Eng Health Med       Date:  2015-07-13       Impact factor: 3.316

10.  Platinum and platinum/iridium electrode properties when used for extracochlear electrical stimulation of the totally deaf.

Authors:  K T Ison; J R Walliker
Journal:  Med Biol Eng Comput       Date:  1987-07       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.