Literature DB >> 7457373

An indication on the biological variability of aerosol total deposition in humans.

G Tarroni, C Melandri, V Prodi, T De Zaiacomo, M Formignani, P Bassi.   

Abstract

A technique for the assessment of the total deposition efficiency, DE, in the human respiratory tract is described. It is based on the use of non-wettable solid spherical monodisperse particles in the 0.3 to 1.5 micron range and on the measurement of particle concentrations in the inhaled and exhaled air. The results of total deposition measurements as a function of particle size taken on 6 volunteers are presented. A wide variability has been found among the subjects; it is discussed and, in contrast with some literature data, there is no apparent correlation with normal expiratory reserve volumes, ERVN. Therefore at 0.6 micron the deposition has been measured at various ERV. The scatter of data is considerable, but it can be greatly reduced if the relative deposition (ratio of the effective DE to DEN, the deposition at "normal" volumes) is expressed as a function of the relative ERV, (the ratio of the effective ERV to the normal ERVN). Measurements have been performed with monodisperse and unipolarly charged particles on two subjects characterized by different DEN and ERVN. The contribution of electrostatic effects to deposition was not distinguishable in the two subjects.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7457373     DOI: 10.1080/15298668091425707

Source DB:  PubMed          Journal:  Am Ind Hyg Assoc J        ISSN: 0002-8894


  7 in total

1.  The Effect of Active Pharmaceutical Ingredients on Aerosol Electrostatic Charges from Pressurized Metered Dose Inhalers.

Authors:  Yang Chen; Paul M Young; David F Fletcher; Hak Kim Chan; Edward Long; David Lewis; Tanya Church; Daniela Traini
Journal:  Pharm Res       Date:  2015-03-19       Impact factor: 4.200

2.  The effect of actuator nozzle designs on the electrostatic charge generated in pressurised metered dose inhaler aerosols.

Authors:  Yang Chen; Paul M Young; David F Fletcher; Hak Kim Chan; Edward Long; David Lewis; Tanya Church; Daniela Traini
Journal:  Pharm Res       Date:  2014-10-01       Impact factor: 4.200

3.  Effect of Relative Humidity on Bipolar Electrostatic Charge Profiles of dry Powder Aerosols.

Authors:  Jiaqi Yu; Jennifer Wong; Ari Ukkonen; Jonna Kannosto; Hak-Kim Chan
Journal:  Pharm Res       Date:  2017-05-24       Impact factor: 4.200

4.  The influence of actuator materials and nozzle designs on electrostatic charge of pressurised metered dose inhaler (pMDI) formulations.

Authors:  Yang Chen; Paul M Young; David F Fletcher; Hak Kim Chan; Edward Long; David Lewis; Tanya Church; Daniela Traini
Journal:  Pharm Res       Date:  2013-12-03       Impact factor: 4.200

5.  Applicability of Bipolar Charge Analyzer (BOLAR) in Characterizing the Bipolar Electrostatic Charge Profile of Commercial Metered Dose Inhalers (MDIs).

Authors:  Sharon Shui Yee Leung; Adam Chong Ming Chiow; Ari Ukkonen; Hak-Kim Chan
Journal:  Pharm Res       Date:  2015-09-03       Impact factor: 4.200

6.  A new method for measuring lung deposition efficiency of airborne nanoparticles in a single breath.

Authors:  Jonas K F Jakobsson; Johan Hedlund; John Kumlin; Per Wollmer; Jakob Löndahl
Journal:  Sci Rep       Date:  2016-11-07       Impact factor: 4.379

7.  Altered deposition of inhaled nanoparticles in subjects with chronic obstructive pulmonary disease.

Authors:  Jonas K F Jakobsson; H Laura Aaltonen; Hanna Nicklasson; Anders Gudmundsson; Jenny Rissler; Per Wollmer; Jakob Löndahl
Journal:  BMC Pulm Med       Date:  2018-08-06       Impact factor: 3.317

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.