Literature DB >> 7440288

Improved esophageal balloon technique for use in infants.

C S Beardsmore, P Helms, J Stocks, D J Hatch, M Silverman.   

Abstract

Esophageal balloons of three different wall thicknesses, two different lengths, and two different diameters were made to assess which type of balloon gave the most consistent and reliable measurements of dynamic compliance (CL) and pulmonary resistance (Rp). The balloons were subjected to in vitro testing to determine their pressure-volume characteristics and working range and then used in infants to compare in vivo results from one balloon to another. The optimal balloon was found to have a length of 35--50 mm, a diameter of 7.6 mm, and a wall thickness of 0.045--0.075 mm. The use of unsuitable balloons or inappropriate volumes of air within the balloon resulted in applied pressures being under-recorded, both in vitro and in vivo, with consequent overestimation of CL and underestimation of Rp during infant lung function tests. Recommendations are made concerning the techniques of making and using esophageal balloons.

Entities:  

Mesh:

Year:  1980        PMID: 7440288     DOI: 10.1152/jappl.1980.49.4.735

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  16 in total

1.  Respiratory compliance in premature babies treated with artificial surfactant (ALEC).

Authors:  C J Morley; A Greenough
Journal:  Arch Dis Child       Date:  1991-04       Impact factor: 3.791

Review 2.  Lung function testing in infancy.

Authors:  A D Milner
Journal:  Arch Dis Child       Date:  1990-05       Impact factor: 3.791

3.  Effect of bracing on respiratory mechanics in mild idiopathic scoliosis.

Authors:  J D Kennedy; C F Robertson; I Hudson; P D Phelan
Journal:  Thorax       Date:  1989-07       Impact factor: 9.139

4.  Disturbance in respiratory mechanics in infants with bronchiolitis.

Authors:  J Seidenberg; I B Masters; I Hudson; A Olinsky; P D Phelan
Journal:  Thorax       Date:  1989-08       Impact factor: 9.139

5.  Contractile and histochemical characteristics of the rabbit diaphragm in elastase-induced emphysema.

Authors:  S Delpierre; M Fornaris; J F Pelissier; M J Payan
Journal:  Lung       Date:  1985       Impact factor: 2.584

6.  Pulmonary compliance in sick low birthweight infants. How reliable is the measurement of oesophageal pressure?

Authors:  A Thomson; J Elliott; M Silverman
Journal:  Arch Dis Child       Date:  1983-11       Impact factor: 3.791

7.  Assessment of the catheter tip pressure transducer for use in infant lung function tests.

Authors:  C S Beardsmore; Y C Wong; J Stocks; M Silverman
Journal:  Med Biol Eng Comput       Date:  1982-11       Impact factor: 2.602

8.  Measurement of pleural pressure with oesophageal catheter-tip micromanometer in anaesthetized humans.

Authors:  D A Chartrand; C Jodoin; J Couture
Journal:  Can J Anaesth       Date:  1991-05       Impact factor: 5.063

9.  Pulmonary sequelae of neonatal respiratory distress in very low birthweight infants: a clinical and physiological study.

Authors:  Y C Wong; C S Beardsmore; M Silverman
Journal:  Arch Dis Child       Date:  1982-06       Impact factor: 3.791

10.  Comparison Study of Airway Reactivity Outcomes due to a Pharmacologic Challenge Test: Impulse Oscillometry versus Least Mean Squared Analysis Techniques.

Authors:  Elena Rodriguez; Charrell M Bullard; Milena H Armani; Thomas L Miller; Thomas H Shaffer
Journal:  Pulm Med       Date:  2013-04-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.