Literature DB >> 2065421

Measurement of pleural pressure with oesophageal catheter-tip micromanometer in anaesthetized humans.

D A Chartrand1, C Jodoin, J Couture.   

Abstract

In spontaneously breathing anaesthetized subjects, we studied a new technique for the measurement of changes in pleural pressure. Seven ASA physical status I patients undergoing general anaesthesia (enflurane 1-2 MAC, nitrous oxide 50%, and oxygen) for minor orthopaedic surgery were studied in the supine position. Changes in oesophageal pressure (delta Pes) were measured by means of a catheter-tip pressure transducer. This micromanometer was positioned according to an occlusion test where delta Pes were compared with the changes in airway opening pressure (delta Pao). Optimizing the signal/noise ratio, we observed a linear relationship between delta Pes and delta Pao. In each patient, the delta Pes/delta Pao relationship was highly reproducible. Using the linear regression analysis to characterize the delta Pes/delta Pao relationship, we have developed a different approach for the positioning of oesophageal catheter. After statistical analysis of the observed delta Pes/delta Pao relationship, a "calibration" factor can be used in order to correct the observed slope of the delta Pes/delta Pao relationship to its theoretical value. We conclude that an oesophageal catheter-tip micromanometer can be used in anaesthetized supine patients to measure changes in pleural pressure.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2065421     DOI: 10.1007/BF03007592

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  7 in total

1.  IMPROVED TECHNIQUE FOR ESTIMATING PLEURAL PRESSURE FROM ESOPHAGEAL BALLOONS.

Authors:  J MILIC-EMILI; J MEAD; J M TURNER; E M GLAUSER
Journal:  J Appl Physiol       Date:  1964-03       Impact factor: 3.531

2.  Relationship of intra-oesophageal pressure to mouth pressure during the measurement of thoracic gas volume in the newborn.

Authors:  A D Milner; R A Saunders; L E Hopkin
Journal:  Biol Neonate       Date:  1978

3.  Measurement of pleural pressure in neonates.

Authors:  M I Asher; A L Coates; J M Collinge; J Milic-Emili
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1982-02

4.  A simple method for assessing the validity of the esophageal balloon technique.

Authors:  A Baydur; P K Behrakis; W A Zin; M Jaeger; J Milic-Emili
Journal:  Am Rev Respir Dis       Date:  1982-11

5.  Measurement of pleural pressure with esophageal balloon in anesthetized humans.

Authors:  B D Higgs; P K Behrakis; D R Bevan; J Milic-Emili
Journal:  Anesthesiology       Date:  1983-10       Impact factor: 7.892

6.  Improved esophageal balloon technique for use in infants.

Authors:  C S Beardsmore; P Helms; J Stocks; D J Hatch; M Silverman
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1980-10

7.  Measurement of pleural pressure at low and high frequencies in normal rabbits.

Authors:  D A Chartrand; T H Ye; J M Maarek; H K Chang
Journal:  J Appl Physiol (1985)       Date:  1987-09
  7 in total
  4 in total

1.  A chest drainage system with a real-time pressure monitoring device.

Authors:  Chih-Hao Chen; Tsang-Pai Liu; Ho Chang; Tung-Sung Huang; Hung-Chang Liu; Chao-Hung Chen
Journal:  J Thorac Dis       Date:  2015-07       Impact factor: 2.895

2.  Patient discomfort in polysomnography with esophageal pressure measurements.

Authors:  Britt Oeverland; Harriet Akre; Kari J Kvaerner; Olav Skatvedt
Journal:  Eur Arch Otorhinolaryngol       Date:  2004-04-30       Impact factor: 2.503

3.  Variations in pulmonary artery occlusion pressure to estimate changes in pleural pressure.

Authors:  Patrick Bellemare; Peter Goldberg; Sheldon A Magder
Journal:  Intensive Care Med       Date:  2007-08-31       Impact factor: 17.440

4.  Detailed measurements of oesophageal pressure during mechanical ventilation with an advanced high-resolution manometry catheter.

Authors:  Per Persson; Rebecca Ahlstrand; Magni Gudmundsson; Alex de Leon; Stefan Lundin
Journal:  Crit Care       Date:  2019-06-13       Impact factor: 9.097

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.