Literature DB >> 6651326

Pulmonary compliance in sick low birthweight infants. How reliable is the measurement of oesophageal pressure?

A Thomson, J Elliott, M Silverman.   

Abstract

Measurements of dynamic lung compliance (Cdyn) were made on 42 occasions in a group of 15 intubated very low birthweight infants with respiratory distress syndrome, using an oesophageal balloon and pneumotachograph system. Values of Cdyn were compared with those of total respiratory system compliance (Crs) using an occlusion technique. Ten very low birthweight infants with no respiratory disease were similarly studied while breathing through a facemask. The occlusion tests for oesophageal balloon assessment were unsatisfactory in 14 of 15 intubated infants, but in only 3 of the 10 normal infants. Values of Cdyn were poorly reproducible and correlated poorly with Crs. We conclude that in sick intubated preterm infants oesophageal pressure (and hence Cdyn) cannot be reliably measured, but that Crs may be a useful parameter of lung stiffness.

Entities:  

Mesh:

Year:  1983        PMID: 6651326      PMCID: PMC1628385          DOI: 10.1136/adc.58.11.891

Source DB:  PubMed          Journal:  Arch Dis Child        ISSN: 0003-9888            Impact factor:   3.791


  20 in total

1.  Effect of diaphragm activity or paralysis on distribution of pleural pressure.

Authors:  E D'Angelo; G Sant'Ambrogio; E Agostoni
Journal:  J Appl Physiol       Date:  1974-09       Impact factor: 3.531

2.  Relationship of intraesophageal pressure to intrapleural pressure in the newborn.

Authors:  R Dinwiddie; G Russell
Journal:  J Appl Physiol       Date:  1972-10       Impact factor: 3.531

3.  Improved lung compliance after ligation of patent ductus arteriosus in hyaline membrane disease.

Authors:  C M Naulty; S Horn; J Conry; G B Avery
Journal:  J Pediatr       Date:  1978-10       Impact factor: 4.406

4.  Improved oxygenation and lung compliance with prone positioning of neonates.

Authors:  M J Wagaman; J G Shutack; A S Moomjian; J G Schwartz; T H Shaffer; W W Fox
Journal:  J Pediatr       Date:  1979-05       Impact factor: 4.406

5.  A simple method of measuring total respiratory system compliance in newborn infants.

Authors:  A Olinsky; A C Bryan; M H Bryan
Journal:  S Afr Med J       Date:  1976-01-31

6.  Pulmonary mechanics in early infancy. Subclinical grunting in low-birth-weight infants.

Authors:  M Lindroth; B Johnson; H Ahlström; N W Svenningsen
Journal:  Pediatr Res       Date:  1981-07       Impact factor: 3.756

7.  Chestwall compliance in full-term and premature infants.

Authors:  T Gerhardt; E Bancalari
Journal:  Acta Paediatr Scand       Date:  1980-05

8.  Improved esophageal balloon technique for use in infants.

Authors:  C S Beardsmore; P Helms; J Stocks; D J Hatch; M Silverman
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1980-10

9.  Individualised continuous distending pressure applied within 6 hours of delivery in infants with respiratory distress syndrome.

Authors:  A K Tanswell; R A Clubb; B T Smith; R W Boston
Journal:  Arch Dis Child       Date:  1980-01       Impact factor: 3.791

10.  Determination of optimal continuous positive airway pressure for the treatment of IRDS by measurement of esophageal pressure.

Authors:  B W Bonta; R Uauy; J B Warshaw; E K Motoyama
Journal:  J Pediatr       Date:  1977-09       Impact factor: 4.406

View more
  5 in total

1.  Respiratory compliance in premature babies treated with artificial surfactant (ALEC).

Authors:  C J Morley; A Greenough
Journal:  Arch Dis Child       Date:  1991-04       Impact factor: 3.791

Review 2.  Intravenous or enteral loop diuretics for preterm infants with (or developing) chronic lung disease.

Authors:  Audra Stewart; Luc P Brion
Journal:  Cochrane Database Syst Rev       Date:  2011-09-07

3.  Mechanical ventilation of the newborn.

Authors:  W Tarnow-Mordi; A Wilkinson
Journal:  Br Med J (Clin Res Ed)       Date:  1986-03-01

4.  Dynamic compliance in preterm ventilated babies.

Authors:  A Greenough; C J Morley
Journal:  Arch Dis Child       Date:  1984-03       Impact factor: 3.791

5.  Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing.

Authors:  Snorri Donaldsson; Markus Falk; Baldvin Jonsson; Thomas Drevhammar
Journal:  PLoS One       Date:  2015-07-20       Impact factor: 3.240

  5 in total