Effect of application force on noninvasive measurements of intracranial pressure.

J D Horbar, S Yeager, A G Philip, J F Lucey.   

Abstract

Application of the Ladd fiberoptic sensor to the anterior fontanel of the human newborn has been used as a method for monitoring intracranial pressure noninvasively. This study measures the effect of varying the force with which the sensor is applied to the fontanel. The Ladd sensor readings of five preterm human infants were continuously monitored while sensor application force was increased in a stepwise manner. The Ladd sensor readings for each infant varied with the force applied. In one infant sensor application was gradually increased while direct measurements of lumbar CSF pressure were made. Ladd sensor readings in this infant increased with increasing application force, while lumbar CSF pressure remained unchanged. It is concluded that readings obtained with the Ladd sensor applied to the anterior fontanel of the human infant depend on the force with which the sensor is applied. The effect of application force must be taken into account if noninvasive measurements of intracranial pressure are to be made with the Ladd device.

Entities:  

Mesh:

Year:  1980        PMID: 7422434

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  10 in total

1.  Non invasive continuous anterior fontanel tension monitoring in neonates.

Authors:  J Sharma; S K Bhargava; S Anand; S K Guha; S Ramji
Journal:  Indian J Pediatr       Date:  1989 Nov-Dec       Impact factor: 1.967

2.  The influence of head position on the intracranial pressure in preterm infants with posthemorrhagic hydrocephalus.

Authors:  B Urlesberger; W Müller; E Ritschl; F Reiterer
Journal:  Childs Nerv Syst       Date:  1991-04       Impact factor: 1.475

3.  New fontanometer for continuous estimation of intracranial pressure in the newborn.

Authors:  M J Rochefort; P Rolfe; A R Wilkinson
Journal:  Arch Dis Child       Date:  1987-02       Impact factor: 3.791

4.  Continuous measurement of subarachnoid pressure in the severely asphyxiated newborn.

Authors:  M I Levene; D H Evans
Journal:  Arch Dis Child       Date:  1983-12       Impact factor: 3.791

5.  Anterior fontanelle pressure monitoring for the evaluation of asymptomatic infants with increased head growth rate.

Authors:  N Massager; J L Wayenberg; C Raftopoulos; C Christophe; D Vermeylen; P Franco
Journal:  Childs Nerv Syst       Date:  1996-01       Impact factor: 1.475

6.  Cerebrospinal fluid pressure during post haemorrhagic ventricular dilatation in newborn infants.

Authors:  A M Kaiser; A G Whitelaw
Journal:  Arch Dis Child       Date:  1985-10       Impact factor: 3.791

7.  Non-invasive measurement of intracranial pressure in the newborn and the infant: the Rotterdam teletransducer.

Authors:  J L Wayenberg; C Raftopoulos; D Vermeylen; A Pardou
Journal:  Arch Dis Child       Date:  1993-11       Impact factor: 3.791

8.  Intracranial pressure in central nervous system infections and cerebral ischaemia of infancy.

Authors:  K J Goitein; Y Amit; H Mussaffi
Journal:  Arch Dis Child       Date:  1983-03       Impact factor: 3.791

9.  Non-invasive ICP monitoring in infants: the Rotterdam Teletransducer revisited.

Authors:  R J Peters; P W Hanlo; R H Gooskens; K P Braun; C A Tulleken; J Willemse
Journal:  Childs Nerv Syst       Date:  1995-04       Impact factor: 1.475

Review 10.  Noninvasive monitoring intracranial pressure - A review of available modalities.

Authors:  Marium Naveed Khan; Hussain Shallwani; Muhammad Ulusyar Khan; Muhammad Shahzad Shamim
Journal:  Surg Neurol Int       Date:  2017-04-05
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.