Literature DB >> 8285752

Non-invasive measurement of intracranial pressure in the newborn and the infant: the Rotterdam teletransducer.

J L Wayenberg1, C Raftopoulos, D Vermeylen, A Pardou.   

Abstract

Knowledge of intracranial pressure may be important in many clinical situations in neonates and young infants. The best way to obtain this information would be a non-traumatic procedure. In order to test the reliability of a new fontanometer, the Rotterdam teletransducer, 25 simultaneous measurements of cerebrospinal fluid (CSF) pressure and anterior fontanelle pressure (AFP) were performed. Mean (SD) difference between CSF pressure and AFP was -0.2 (1.8) mm Hg (95% confidence interval from -0.48 to -0.88 mm Hg). The AFP was also measured in 60 healthy children (15 premature, 30 term newborn babies, and 15 infants). The different aspects of AFP were analysed and normal values computed. These results suggest that the Rotterdam teletransducer gives reliable continuous information about intracranial pressure and can be used in clinical practice. Interpretation of AFP plots must take the influence of postconceptional age and the physiological occurrence of pressure waves into account.

Entities:  

Mesh:

Year:  1993        PMID: 8285752      PMCID: PMC1029591          DOI: 10.1136/adc.69.5_spec_no.493

Source DB:  PubMed          Journal:  Arch Dis Child        ISSN: 0003-9888            Impact factor:   3.791


  18 in total

1.  Compartmental analysis of compliance and outflow resistance of the cerebrospinal fluid system.

Authors:  A Marmarou; K Shulman; J LaMorgese
Journal:  J Neurosurg       Date:  1975-11       Impact factor: 5.115

2.  The relationship of blood flow velocity fluctuations to intracranial pressure B waves.

Authors:  D W Newell; R Aaslid; R Stooss; H J Reulen
Journal:  J Neurosurg       Date:  1992-03       Impact factor: 5.115

3.  B-waves in healthy persons.

Authors:  D Mautner-Huppert; R L Haberl; U Dirnagl; A Villringer; P Schmiedek; K Einhäupl
Journal:  Neurol Res       Date:  1989-12       Impact factor: 2.448

4.  Experimental identification of the subararachnoid and subpial compartments by intracranial pressure measurements.

Authors:  A Schettini; E K Walsh
Journal:  J Neurosurg       Date:  1974-05       Impact factor: 5.115

5.  Non-invasive method for measuring intracranial pressure in normal newborn infants.

Authors:  R O Robinson; P Rolfe; P Sutton
Journal:  Dev Med Child Neurol       Date:  1977-06       Impact factor: 5.449

6.  Lundberg's B waves as a feature of normal intracranial pressure.

Authors:  G Martin
Journal:  Surg Neurol       Date:  1978-06

7.  Cerebral perfusion pressure studies in healthy preterm and term newborn infants.

Authors:  T N Raju; U V Doshi; D Vidyasagar
Journal:  J Pediatr       Date:  1982-01       Impact factor: 4.406

8.  Intracranial pressure. Sequential measurements in full-term and preterm infants.

Authors:  A G Philip; J G Long; S M Donn
Journal:  Am J Dis Child       Date:  1981-06

9.  The fontanelle tonometer: a noninvasive method for measurement of intracranial pressure.

Authors:  J A Menke; R Miles; M McIlhany; M Bashiru; C Chua; E Schwied; T G Menten; N N Khanna
Journal:  J Pediatr       Date:  1982-06       Impact factor: 4.406

10.  Effect of application force on noninvasive measurements of intracranial pressure.

Authors:  J D Horbar; S Yeager; A G Philip; J F Lucey
Journal:  Pediatrics       Date:  1980-09       Impact factor: 7.124

View more
  2 in total

Review 1.  Noninvasive assessment of cerebrospinal fluid pressure.

Authors:  Beau B Bruce
Journal:  J Neuroophthalmol       Date:  2014-09       Impact factor: 3.042

2.  Anterior fontanelle pressure monitoring for the evaluation of asymptomatic infants with increased head growth rate.

Authors:  N Massager; J L Wayenberg; C Raftopoulos; C Christophe; D Vermeylen; P Franco
Journal:  Childs Nerv Syst       Date:  1996-01       Impact factor: 1.475

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.