Non-invasive ICP monitoring in infants: the Rotterdam Teletransducer revisited.

R J Peters1, P W Hanlo, R H Gooskens, K P Braun, C A Tulleken, J Willemse.   

Abstract

Measurement of intracranial pressure (ICP) is important in patients at risk of raised ICP, as in hydrocephalus. Ideally, it should be non-invasive, thus avoiding the risk of infection and other complications: Such is provided by measurement of ICP through the anterior fontanelle. There are several methods of measuring anterior fontanelle pressure (AFP); those most frequently used are based on the applanation principle. An evaluation of AFP measurement devices resulted in the choice of the Rotterdam Teletransducer (RTT) to be used in our study of children with hydrocephalus. The literature contains little information on the accuracy or validation of the AFP measurements using the RTT. Therefore, the physical qualities of the RTT were reassessed, using a specially developed calibration device. The results of this study demonstrate that membrane temperature does not have any effect on the measured pressure. The thermal stabilization time of the RTT was found to be 3 h after switching on. Insufficient thermal stabilization results in a pressure underestimation of up to 3 mmHg. Furthermore, a maximum inaccuracy of 2.6 mmHg, after calibration and readjustment of the transducer, was calculated. Validation of the equipment was achieved by simultaneous AFP/ICP measurements in hydrocephalic patients showing high correlations (r = 0.96-0.98). The discussion suggests a measurement protocol as a means of increasing the reliability of RTT measurements.

Entities:  

Mesh:

Year:  1995        PMID: 7621481     DOI: 10.1007/bf00277655

Source DB:  PubMed          Journal:  Childs Nerv Syst        ISSN: 0256-7040            Impact factor:   1.475


  15 in total

1.  A new instrument for noninvasive measurement of intracranial pressure through the anterior fontanel. I. Preliminary report.

Authors:  T Hayashi; S Kuramoto; E Honda; S Anegawa
Journal:  Childs Nerv Syst       Date:  1987       Impact factor: 1.475

2.  Experimental approach for monitoring surface brain pressure.

Authors:  A Schettini; L McKay; R Majors; J Mahig; A H Nevis
Journal:  J Neurosurg       Date:  1971-01       Impact factor: 5.115

3.  Clinical fontanometry in the newborn.

Authors:  A Mehta; B M Wright; C Shore
Journal:  Lancet       Date:  1988-04-02       Impact factor: 79.321

4.  Non-invasive intracranial pressure monitoring. A technique for reproducible fontanelle pressure measurements.

Authors:  D A De Jong; A I Maas; E v d Voort
Journal:  Z Kinderchir       Date:  1984-08

5.  Measurement of fontanelle pressure (Part I). A new instrument for non-invasive measurement of intracranial pressure via the anterior fontanelle.

Authors:  E Honda
Journal:  Kurume Med J       Date:  1984

6.  Methods of measuring intracranial pressure via the fontanelle without puncture.

Authors:  S R Wealthall; R Smallwood
Journal:  J Neurol Neurosurg Psychiatry       Date:  1974-01       Impact factor: 10.154

7.  The Rotterdam Teletransducer: state of the device.

Authors:  A I Maas
Journal:  Z Kinderchir       Date:  1985-12

8.  Effect of application force on noninvasive measurements of intracranial pressure.

Authors:  J D Horbar; S Yeager; A G Philip; J F Lucey
Journal:  Pediatrics       Date:  1980-09       Impact factor: 7.124

9.  The Rotterdam Teletransducer: state of the device.

Authors:  A I Maas; D A de Jong
Journal:  Acta Neurochir (Wien)       Date:  1986       Impact factor: 2.216

View more
  2 in total

Review 1.  Non-invasive intracranial pressure assessment.

Authors:  Llewellyn C Padayachy
Journal:  Childs Nerv Syst       Date:  2016-07-21       Impact factor: 1.475

2.  Relationship between anterior fontanelle pressure measurements and clinical signs in infantile hydrocephalus.

Authors:  P W Hanlo; R H Gooskens; J A Faber; R J Peters; A A Hermsen; I J Nijhuis; W P Vandertop; C A Tulleken; J Willemse
Journal:  Childs Nerv Syst       Date:  1996-04       Impact factor: 1.475

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.