Literature DB >> 7379421

Evaluation of left ventricular performance by gated radionuclide angiography.

B H Greenberg, D Drew, E H Botvinick, J A Werner, S C Klausner, D M Shames, W W Parmley.   

Abstract

Gated radionuclide angiography (RVG) in orthogonal projections was used to evaluate left ventricular volume, ejection fraction, and segmental wall motion. Images of the left ventricle at end-diastole and end-systole were outlined in two projections using a simple manual method. The perimeter drawings were digitized on a desktop computer, interfaced to an XY recorder and left ventricular volumes and ejection fraction calculated. The results were compared to contrast left ventriculography (CVG) in the same projections. RVG and CVG gave similar results for end-diastolic volume (r = .87, P less than 0.001), end-systolic volume (r = .95, P less than 0.001), and ejection fraction (r = .89, P less than 0.001) over a wide range of values. In 92% of all left ventricular segments analyzed, RVG and CVG showed only minor differences in the analysis of wall motion. Reproducibility of the method by a trained observer was excellent. Interobserver trials demonstrated that less well-trained observers consistently over- or underestimated volumes, emphasizing the need for prior experience in RVG analysis. Use of this manual method for analysis of gated equilibrium RVG in orthogonal projections appears to be a reasonably accurate, reproducible method for evaluating left ventricular function.

Mesh:

Year:  1980        PMID: 7379421     DOI: 10.1097/00003072-198006000-00003

Source DB:  PubMed          Journal:  Clin Nucl Med        ISSN: 0363-9762            Impact factor:   7.794


  6 in total

Review 1.  Nonechocardiographic imaging in evaluation for cardiac resynchronization therapy.

Authors:  Wael AlJaroudi; Ji Chen; Wael A Jaber; Steven G Lloyd; Manuel D Cerqueira; Thomas Marwick
Journal:  Circ Cardiovasc Imaging       Date:  2011-05       Impact factor: 7.792

2.  Assessment of ventricular function by radionuclide angiography in patients receiving 4'-epidoxorubicin and mitoxantrone.

Authors:  D A Vorobiof; M Iturralde; G Falkson
Journal:  Cancer Chemother Pharmacol       Date:  1985       Impact factor: 3.333

3.  Reproducibility of ejection fraction measurements by gated equilibrium blood pool scintigraphy.

Authors:  G A Heidendal; P D Bezemer; P A Koopman; W den Hollander; G J Teule; E E van der Wall; A Hasman
Journal:  Eur J Nucl Med       Date:  1983

4.  Effects of coronary artery bypass grafting on left ventricular function assessed by multiple gated ventricular scintigraphy.

Authors:  N C Taylor; R W Barber; P Crossland; T A English; E P Wraight; M C Petch
Journal:  Br Heart J       Date:  1983-08

5.  Relation of left-ventricular dyssynchrony by phase analysis of gated SPECT images and cardiovascular events in patients with implantable cardiac defibrillators.

Authors:  Wael A Aljaroudi; Fadi G Hage; Daniel Hermann; Harish Doppalapudi; Rajesh Venkataraman; Jaekyeong Heo; Ami E Iskandrian
Journal:  J Nucl Cardiol       Date:  2010-03-19       Impact factor: 5.952

6.  The variable functional effects of the pacing site in normal and scarred ventricles.

Authors:  Luisa Muñoz del Romeral; Carol Stillson; Michael Lesh; Elias Botvinick
Journal:  J Nucl Cardiol       Date:  2009 Nov-Dec       Impact factor: 5.952

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.