Literature DB >> 7364859

Compliance: a continuing problem with vascular grafts.

C E Kinley, A E Marble.   

Abstract

Compliance mismatch between host artery and synthetic vascular substitutes has rarely been mentioned in the literature as a possible cause of suture line disruption and damage to endothelial and platelet cells. In this paper we have attempted to elucidate on how compliance mismatch can predispose: (1) anastomotic rupture, (2) flow induced shear stres and, (3) reduced distal perfusion. We have concluded that in order to minimize all three of these factors the compliance of the vascular substitute should be equivalent to the host artery to which it is to be anastomosed. It appears that the factor which is most seriously affected by the compliance mismatch is the flow regimen in that flow separation regions forms at the distal anastomosis. Shear stresses, due to eddies in these regions of flow separation, are of significant magnitude to destroy endothelial cells lining the vascular wall and platelets existing in the boundary layer.

Entities:  

Mesh:

Year:  1980        PMID: 7364859

Source DB:  PubMed          Journal:  J Cardiovasc Surg (Torino)        ISSN: 0021-9509            Impact factor:   1.888


  9 in total

1.  Microscopic and immunohistological studies on intimal hyperplasia of the arterially implanted autovein graft and its anastomosis in dogs.

Authors:  D R Shrestha; H Shiroma; Y Kamada; A Kusaba
Journal:  Surg Today       Date:  1992       Impact factor: 2.549

2.  Effect of compliance mismatch on flow disturbances in a model of an arterial graft replacement.

Authors:  F Miyawaki; T V How; D Annis
Journal:  Med Biol Eng Comput       Date:  1990-09       Impact factor: 2.602

3.  Effects of laser thermal angioplasty on arterial contractions and mechanics.

Authors:  P M Consigny; G P Teitelbaum; G A Gardiner; W D Kerns
Journal:  Cardiovasc Intervent Radiol       Date:  1989 Mar-Apr       Impact factor: 2.740

4.  In vivo measurement of arterial pre-tension.

Authors:  S I Green; G S Schajer; D R Parker; A J Post; Y N Hsiang
Journal:  Med Biol Eng Comput       Date:  1995-11       Impact factor: 2.602

5.  Mechanical property characterization of electrospun recombinant human tropoelastin for vascular graft biomaterials.

Authors:  Kathryn A McKenna; Monica T Hinds; Rebecca C Sarao; Ping-Cheng Wu; Cheryl L Maslen; Robert W Glanville; Darcie Babcock; Kenton W Gregory
Journal:  Acta Biomater       Date:  2011-08-06       Impact factor: 8.947

6.  High compliance vascular grafts based on semi-interpenetrating networks.

Authors:  David K Dempsey; Roya M Nezarati; Calvin E Mackey; Elizabeth M Cosgriff-Hernandez
Journal:  Macromol Mater Eng       Date:  2014-12       Impact factor: 4.367

7.  In vivo determination of human arterial compliance: preliminary investigation of a new technique.

Authors:  M E Hansen; E K Yucel; J Megerman; G J L'Italien; W M Abbott; A C Waltman
Journal:  Cardiovasc Intervent Radiol       Date:  1994 Jan-Feb       Impact factor: 2.740

8.  Flow dynamics across end-to-end vascular bypass graft anastomoses.

Authors:  Y H Kim; K B Chandran; T J Bower; J D Corson
Journal:  Ann Biomed Eng       Date:  1993 Jul-Aug       Impact factor: 3.934

9.  Finite-element analysis of arterial anastomoses with vein, Dacron and PTFE grafts.

Authors:  K B Chandran; D Gao; G Han; H Baraniewski; J D Corson
Journal:  Med Biol Eng Comput       Date:  1992-07       Impact factor: 2.602

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.