Literature DB >> 1487942

Finite-element analysis of arterial anastomoses with vein, Dacron and PTFE grafts.

K B Chandran1, D Gao, G Han, H Baraniewski, J D Corson.   

Abstract

A finite-element simulation of an end-to-end artery/graft anastomosis has been presented in this study to evaluate the distribution of compliance and stresses in the vicinity of the anastomosis due to any mismatch in compliance characteristics. The arterial wall was assumed to be made of linear isotropic elastic material in this simplified model and a static analysis was performed with a mean arterial pressure loading of the artery-graft model. Anastomoses to vein grafts and both Dacron and polytetrafluoroethylene (PTFE) grafts were studied. The results suggested the presence of a hypercompliant zone on the arterial side and a region of high tensile stresses in the wall on the graft side of the anastomosis. The presence of a hypercompliant zone has been reported from previous in vivo studies. The hypercompliance was larger with Dacron and PTFE grafts compared with that with the vein graft. However, larger tensile stresses were present in the wall of the vein graft compared with the synthetic grafts. The analysis further showed that increasing the diameter of the graft compared with the host artery to increase flow through the implant will result in a significant increase in the hypercompliance on the arterial side. Such simulation studies may prove valuable in studying the effects of compliance mismatch and suggest ways to improve the design of small diameter vascular grafts.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1487942     DOI: 10.1007/bf02446179

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  8 in total

1.  Effect of compliance and diameter on stress at arterial anastomoses.

Authors:  M F Teodori; V G Rodgers; A M Brant; H S Borovetz; M W Webster; D L Steed; A B Peitzman
Journal:  Curr Surg       Date:  1986 Nov-Dec

2.  Postsurgical changes in arterial compliance.

Authors:  J E Hasson; J Megerman; W M Abbott
Journal:  Arch Surg       Date:  1984-07

3.  Increased compliance near vascular anastomoses.

Authors:  J E Hasson; J Megerman; W M Abbott
Journal:  J Vasc Surg       Date:  1985-05       Impact factor: 4.268

4.  Compliance: a continuing problem with vascular grafts.

Authors:  C E Kinley; A E Marble
Journal:  J Cardiovasc Surg (Torino)       Date:  1980 Mar-Apr       Impact factor: 1.888

5.  Suture technique and para-anastomotic compliance.

Authors:  J E Hasson; J Megerman; W M Abbott
Journal:  J Vasc Surg       Date:  1986-04       Impact factor: 4.268

6.  Matched elastic properties and successful arterial grafting.

Authors:  R Walden; G J L'Italien; J Megerman; W M Abbott
Journal:  Arch Surg       Date:  1980-10

7.  The effect of wall mechanical properties on patency of arterial grafts.

Authors:  I G Kidson
Journal:  Ann R Coll Surg Engl       Date:  1983-01       Impact factor: 1.891

8.  Pathogenesis of anastomotic aneurysms.

Authors:  H Gaylis
Journal:  Surgery       Date:  1981-09       Impact factor: 3.982

  8 in total
  7 in total

1.  Why Patencies of Femoropopliteal Bypass Grafts with Distal End-to-End Anastomosis are Comparable with End-to-Side Anastomosis.

Authors:  Marco Hoedt; Thien How; Paul Poyck; Cees Wittens
Journal:  Ann Thorac Cardiovasc Surg       Date:  2015-01-26       Impact factor: 1.520

2.  Computationally optimizing the compliance of multilayered biomimetic tissue engineered vascular grafts.

Authors:  Ehab Akram Tamimi; Diana Catalina Ardila; Burt D Ensley; Robert S Kellar; Jonathan Vande Geest
Journal:  J Biomech Eng       Date:  2019-02-19       Impact factor: 2.097

3.  A new model for the artificial aorta blood vessels using double-sided radial functionally graded biomaterials.

Authors:  M Salimi Bani; H Asgharzadeh Shirazi; M R Ayatollahi; Alireza Asnafi
Journal:  Med Biol Eng Comput       Date:  2016-09-15       Impact factor: 2.602

4.  Vascular Pressure-Flow Measurement Using CB-PDMS Flexible Strain Sensor.

Authors:  Hao Chong; Jiongcheng Lou; Kath M Bogie; Christian A Zorman; Steve J A Majerus
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-10-10       Impact factor: 3.833

5.  Flow dynamics across end-to-end vascular bypass graft anastomoses.

Authors:  Y H Kim; K B Chandran; T J Bower; J D Corson
Journal:  Ann Biomed Eng       Date:  1993 Jul-Aug       Impact factor: 3.934

6.  A computational fluid-structure interaction model to predict the biomechanical properties of the artificial functionally graded aorta.

Authors:  Arezoo Khosravi; Milad Salimi Bani; Hossein Bahreinizade; Alireza Karimi
Journal:  Biosci Rep       Date:  2016-12-23       Impact factor: 3.840

7.  The combined impact of mechanical factors on the wall stress of the human ascending aorta - a finite elements study.

Authors:  Tomasz Plonek; Malgorzata Zak; Karolina Burzynska; Bartosz Rylski; Anna Gozdzik; Wojciech Kustrzycki; Friedhelm Beyersdorf; Marek Jasinski; Jaroslaw Filipiak
Journal:  BMC Cardiovasc Disord       Date:  2017-12-20       Impact factor: 2.298

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.