Literature DB >> 7360790

The Monte Carlo calculation of integral radiation dose in xeromammography.

D R Dance.   

Abstract

A Monte Carlo computer program has been developed for the computation of integral radiation dose to the breast in xeromammography. The results are given in terms of the integral dose per unit area of the breast per unit incident exposure. The calculations have been made for monoenergetic incident photons and the results integrated over a variety of X-ray spectra from both tungsten and molybdenum targets. This range incorporates qualities used in conventional and xeromammography. The program includes the selenium plate used in xeroradiography; the energy absorbed in this detector has also been investigated. The latter calculations have been used to predict relative values of exposure and of integral dose to the breast for xeromammograms taken at various radiation qualities. The results have been applied to recent work on the reduction of patient exposure in xeromammography by the addition of aluminium filters to the X-ray beam.

Entities:  

Mesh:

Year:  1980        PMID: 7360790     DOI: 10.1088/0031-9155/25/1/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Evaluation of an improved algorithm for producing realistic 3D breast software phantoms: application for mammography.

Authors:  K Bliznakova; S Suryanarayanan; A Karellas; N Pallikarakis
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

2.  Radiation dose to organs and tissues from mammography: Monte Carlo and phantom study.

Authors:  Ioannis Sechopoulos; Sankararaman Suryanarayanan; Srinivasan Vedantham; Carl J D'Orsi; Andrew Karellas
Journal:  Radiology       Date:  2007-12-04       Impact factor: 11.105

3.  Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry.

Authors:  Ioannis Sechopoulos; Kristina Bliznakova; Xulei Qin; Baowei Fei; Steve Si Jia Feng
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

4.  The effect of skin thickness determined using breast CT on mammographic dosimetry.

Authors:  Shih-Ying Huang; John M Boone; Kai Yang; Alexander L C Kwan; Nathan J Packard
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

5.  Dosimetry in x-ray-based breast imaging.

Authors:  David R Dance; Ioannis Sechopoulos
Journal:  Phys Med Biol       Date:  2016-09-12       Impact factor: 3.609

6.  Technical note: Skin thickness measurements using high-resolution flat-panel cone-beam dedicated breast CT.

Authors:  Linxi Shi; Srinivasan Vedantham; Andrew Karellas; Avice M O'Connell
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.