Literature DB >> 7338535

Sensitive three-parameter flow-cytometric detection of abnormal cells in human cervical cancers: a pilot study.

G Valet, M G Ormerod, H H Warnecke, G Benker, G Ruhenstroth-Bauer.   

Abstract

The cell volume, the DNA, and the carcino-embryonic (CEA) or epithelial-membrane (EMA) antigen of formaldehyde-fixed human cervical cells from 21 malignant cervix tumors and 11 normal patients were measured simultaneously with a Fluvo-Metricell flow cytometer. The simultaneous cell volume and DNA measurement provided the distinction of morphologically intact cells from cell debris, the determination of the cell cycle phase combined with the detection of aneuploid cells, and the distinct of inflammatory cells from parenchymal and tumor cells. Malignant samples were recognized because they contained more than 0.5% CEA positive cells which were of intermediate size. CEA and EMA expression in the malignant samples was not linked. The false positive rate in a total of 32 samples was 6.3% when the sum of CEA and EMA positive cells of each cell sample was calculated. No false negative malignant sample was observed.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7338535     DOI: 10.1007/bf00410669

Source DB:  PubMed          Journal:  J Cancer Res Clin Oncol        ISSN: 0171-5216            Impact factor:   4.553


  20 in total

1.  Progress report of the TUDAB project for automated cancer cell detection.

Authors:  W Abmayr; G Burger; H J Soost
Journal:  J Histochem Cytochem       Date:  1979-01       Impact factor: 2.479

2.  The diagnostic significance of nuclear deoxyribonucleic acid measurement in automated cytology.

Authors:  E Sprenger; S Witte
Journal:  J Histochem Cytochem       Date:  1979-01       Impact factor: 2.479

3.  Imaging in flow.

Authors:  D B Kay; J L Cambier; L L Wheeless
Journal:  J Histochem Cytochem       Date:  1979-01       Impact factor: 2.479

4.  A new antigen on the epithelial membrane: its immunoperoxidase localisation in normal and neoplastic tissue.

Authors:  E Heyderman; K Steele; M G Ormerod
Journal:  J Clin Pathol       Date:  1979-01       Impact factor: 3.411

5.  Fast imaging in flow: a means of combining flow-cytometry and image analysis.

Authors:  V Kachel; G Benker; K Lichtnau; G Valet; E Glossner
Journal:  J Histochem Cytochem       Date:  1979-01       Impact factor: 2.479

6.  Quantitative cytology of the positive region in flow sorted vaginal smears.

Authors:  K Goerttler; M Stöhr
Journal:  J Histochem Cytochem       Date:  1979-01       Impact factor: 2.479

7.  The use of percent volume analysis in Coulter sizing of cells in gynecologic cytopathologic cell suspensions.

Authors:  J F Leary; P Todd; G S Ross; R Mortel; G S Fleagle
Journal:  Anal Quant Cytol       Date:  1979 Nov-Dec

8.  Receptor binding of fluorescein labeled steroids.

Authors:  G Daxenbichler; H J Grill; R Domanig; E Moser; O Dapunt
Journal:  J Steroid Biochem       Date:  1980-05       Impact factor: 4.292

9.  Simultaneous flow cytometric DNA and volume measurements of bone marrow cells as sensitive indicator of abnormal proliferation patterns in rat leukemias.

Authors:  G Valet; B Fischer; A Sundergeld; G Hanser; V Kachel; G Ruhenstroth-Bauer
Journal:  J Histochem Cytochem       Date:  1979-01       Impact factor: 2.479

10.  Estrogen receptor cytochemistry by fluorescent estrogen.

Authors:  I Nenci; W B Dandliker; C Y Meyers; E Marchetti; A Marzola; G Fabris
Journal:  J Histochem Cytochem       Date:  1980-10       Impact factor: 2.479

View more
  4 in total

1.  The flow cytometer.

Authors:  A H Wyllie
Journal:  Br Med J (Clin Res Ed)       Date:  1987-01-17

2.  Tissue preparation for simultaneous flow cytometric quantitation of tumour associated antigens and DNA in solid tumours.

Authors:  P A van Dam; J V Watson; D G Lowe; H Cox; M Curling; J H Shepherd
Journal:  J Clin Pathol       Date:  1990-10       Impact factor: 3.411

3.  New possibilities of cytostatic drug testing on patient tumor cells by flow cytometry.

Authors:  G Valet; H H Warnecke; H Kahle
Journal:  Blut       Date:  1984-07

4.  A new method for fast blood cell counting and partial differentiation by flow cytometry.

Authors:  G Valet
Journal:  Blut       Date:  1984-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.