Fast imaging in flow: a means of combining flow-cytometry and image analysis.

V Kachel, G Benker, K Lichtnau, G Valet, E Glossner.   

Abstract

The morphological identification of cells by flow cytometry is difficult. Usually cell sorting and microscopical analysis have to be used in addition. Morphological analysis is simplified by taking cell pictures from a range of particular interest immediately during flow cytometric analysis. Instruments using the video scanning technique for fluorescence imaging are slow and expensive (8, 10). Morphological information can also be obtained by transmission imaging of cells in flow, which requires shorter exposure times. Therefore a cell volume activated flow imaging device has been developed which operates at flow speeds up to 5 m/sec and which depicts transmission images of selected cells on a 16-mm film by a nsec flashlamp illumination. An electronic unit detects the particles in the optically accessible orifice, performs the pulse height analysis, triggers the flashlamp if particles are in the preselcted range of interest and feeds the film. The instrument is capable of delivering up to 150 pictures per second and works either as a flow microscope in which the cells in the preselected volume range are directly observed, or as a picture system in which the cell pictures are stored on the 16-mm film for documentation or for image analysis.

Mesh:

Substances:

Year:  1979        PMID: 374598     DOI: 10.1177/27.1.374598

Source DB:  PubMed          Journal:  J Histochem Cytochem        ISSN: 0022-1554            Impact factor:   2.479


  4 in total

Review 1.  Review: imaging technologies for flow cytometry.

Authors:  Yuanyuan Han; Yi Gu; Alex Ce Zhang; Yu-Hwa Lo
Journal:  Lab Chip       Date:  2016-11-29       Impact factor: 6.799

Review 2.  Microfluidic microscopy-assisted label-free approach for cancer screening: automated microfluidic cytology for cancer screening.

Authors:  Veerendra Kalyan Jagannadh; G Gopakumar; Gorthi R K Sai Subrahmanyam; Sai Siva Gorthi
Journal:  Med Biol Eng Comput       Date:  2016-07-22       Impact factor: 2.602

3.  Sensitive three-parameter flow-cytometric detection of abnormal cells in human cervical cancers: a pilot study.

Authors:  G Valet; M G Ormerod; H H Warnecke; G Benker; G Ruhenstroth-Bauer
Journal:  J Cancer Res Clin Oncol       Date:  1981       Impact factor: 4.553

4.  High throughput imaging cytometer with acoustic focussing.

Authors:  Robert Zmijan; Umesh S Jonnalagadda; Dario Carugo; Yu Kochi; Elizabeth Lemm; Graham Packham; Martyn Hill; Peter Glynne-Jones
Journal:  RSC Adv       Date:  2015-10-01       Impact factor: 3.361

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.