Literature DB >> 7333128

Non-uniform swelling properties of the corneal stroma.

D Lee, G Wilson.   

Abstract

The swelling properties of the anterior and posterior stroma of bovine and rabbit corneas were examined by three different methods. The results show that the posterior stroma can swell more than the anterior stroma. Also, at a given swelling pressure, the posterior stroma is more hydrated than the anterior stroma. In a third experiment it is demonstrated that the posterior stroma is also more hydrated in the living eye. It is concluded that the stroma is not a homogeneous structure. The superficial stroma has different physiological properties from the deep stroma. These differences must be taken into account in theoretical models of corneal deturgescence.

Entities:  

Mesh:

Year:  1981        PMID: 7333128     DOI: 10.3109/02713688109019986

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  11 in total

1.  Brillouin optical microscopy for corneal biomechanics.

Authors:  Giuliano Scarcelli; Roberto Pineda; Seok Hyun Yun
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-01-20       Impact factor: 4.799

2.  Keratocyte and subbasal nerve density after penetrating keratoplasty.

Authors:  Sanjay V Patel; Jay C Erie; Jay W McLaren; William M Bourne
Journal:  Trans Am Ophthalmol Soc       Date:  2007

3.  Anterior keratocyte depletion in fuchs endothelial dystrophy.

Authors:  Laura A Hecker; Jay W McLaren; Lori A Bachman; Sanjay V Patel
Journal:  Arch Ophthalmol       Date:  2011-01-10

4.  A structural model for the in vivo human cornea including collagen-swelling interaction.

Authors:  Xi Cheng; Steven J Petsche; Peter M Pinsky
Journal:  J R Soc Interface       Date:  2015-08-06       Impact factor: 4.118

5.  An explanation for the central to peripheral thickness variation in the mouse cornea.

Authors:  Johanna Tukler Henriksson; Anthony J Bron; Jan Pg Bergmanson
Journal:  Clin Exp Ophthalmol       Date:  2011-09-19       Impact factor: 4.207

6.  The measurement of ox corneal swelling pressure by osmometry.

Authors:  S Hodson; D O'Leary; S Watkins
Journal:  J Physiol       Date:  1991-03       Impact factor: 5.182

7.  Differences in the TGF-{beta}1-induced profibrotic response of anterior and posterior corneal keratocytes in vitro.

Authors:  Holly B Hindman; Jennifer N Swanton; Richard P Phipps; Patricia J Sime; Krystel R Huxlin
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-11-11       Impact factor: 4.799

8.  Structural characterization of edematous corneas by forward and backward second harmonic generation imaging.

Authors:  Chiu-Mei Hsueh; Wen Lo; Wei-Liang Chen; Vladimir A Hovhannisyan; Guang-Yu Liu; Sheng-Shun Wang; Hsin-Yuan Tan; Chen-Yuan Dong
Journal:  Biophys J       Date:  2009-08-19       Impact factor: 4.033

9.  Laser In Situ Keratomileusis (LASIK) Combined with Prophylactic Corneal Cross-Linking for Correction of Myopia: Regional Analysis of Corneal Morphology.

Authors:  Jia Zhang; Tong Chen; Junjie Wang; Fangjun Bao; Wen Chen; Aleksandar Stojanovic; Qinmei Wang; Shihao Chen
Journal:  Ophthalmol Ther       Date:  2022-05-09

10.  The effect of riboflavin/UVA collagen cross-linking therapy on the structure and hydrodynamic behaviour of the ungulate and rabbit corneal stroma.

Authors:  Sally Hayes; Christina S Kamma-Lorger; Craig Boote; Robert D Young; Andrew J Quantock; Anika Rost; Yasmeen Khatib; Jonathan Harris; Naoto Yagi; Nicholas Terrill; Keith M Meek
Journal:  PLoS One       Date:  2013-01-17       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.