Literature DB >> 7200741

Continuous monitoring of mixed venous oxygen saturation in critically ill patients.

P L Baele, J C McMichan, H M Marsh, J C Sill, P A Southorn.   

Abstract

A new pulmonary artery balloon flow-directed catheter combines a fiberoptic photometric system for continuous display of mixed venous blood oxygen saturation (SvO2) with the capacity for hemodynamic measurements including thermodilution cardiac output estimation. This oximetry system was studied to determine its accuracy, reliability, and usefulness in the surgical intensive care unit (ICU). Twenty-two catheters were tested, but only 17 were successfully placed in 16 patients. There were technical problems associated with 10 catheters and on six occasions these necessitated the use of another catheter. The catheter values for SvO2 were closely related (r = 0.9516) to those obtained from a laboratory Co-oximeter. Continuous monitoring of SvO2 is accurate and valuable as a warning system for deterioration in cardiopulmonary function and as an indicator of the effects of various therapeutic maneuvers in critically ill patients.

Entities:  

Mesh:

Year:  1982        PMID: 7200741

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  17 in total

1.  Continuous mixed venous oxygen saturation monitoring during general anesthesia.

Authors:  O Kemmotsu; S Yokota; M Mizushima; T Yamamura; M Ueda; S Kaseno; F Nakata; N Sakuraya
Journal:  J Anesth       Date:  1989-09-01       Impact factor: 2.078

2.  Simultaneous in vivo comparison of two-versus three-wavelength mixed venous (Svo2) oximetry catheters.

Authors:  F Bongard; T S Lee; T Leighton; S Y Liu
Journal:  J Clin Monit       Date:  1995-09

3.  Continuous monitoring of mixed venous oxygen saturation in septic shock.

Authors:  D Heiselman; J Jones; L Cannon
Journal:  J Clin Monit       Date:  1986-10

4.  Continuous monitoring of mixed venous oxygen saturation in infants after cardiac surgery.

Authors:  D Schranz; S Schmitt; H Oelert; F Schmid; R Huth; B Zimmer; A Schuind; K Vogel; H Stopfkuchen; B K Jüngst
Journal:  Intensive Care Med       Date:  1989       Impact factor: 17.440

5.  Continuous central venous oxygen saturation (ScvO2) measurement using a fibre optic catheter in newborn infants.

Authors:  M A van der Hoeven; W J Maertzdorf; C E Blanco
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-05       Impact factor: 5.747

6.  Continuous venous oximetry in surgical patients.

Authors:  L D Nelson
Journal:  Ann Surg       Date:  1986-03       Impact factor: 12.969

7.  Functional residual capacity as a noninvasive indicator of optimal positive end-expiratory pressure.

Authors:  T D East; J C in't Veen; N L Pace; S McJames
Journal:  J Clin Monit       Date:  1988-04

8.  CT contrast predicts pancreatic cancer treatment response to verteporfin-based photodynamic therapy.

Authors:  Michael Jermyn; Scott C Davis; Hamid Dehghani; Matthew T Huggett; Tayyaba Hasan; Stephen P Pereira; Stephen G Bown; Brian W Pogue
Journal:  Phys Med Biol       Date:  2014-03-20       Impact factor: 3.609

9.  The reliability of continuous measurement of mixed venous oxygen saturation during exercise in patients with chronic heart failure.

Authors:  Boudewijn T H M Sleutjes; Hareld M C Kemps; Eric J M Thijssen; Frans N van de Vosse; Goof Schep; Chris H Peters; Pieter F F Wijn
Journal:  Eur J Appl Physiol       Date:  2007-10-24       Impact factor: 3.078

10.  Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill.

Authors:  Konrad Reinhart; Hans-Jörg Kuhn; Christiane Hartog; Donald L Bredle
Journal:  Intensive Care Med       Date:  2004-06-09       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.