Indirect measurement of blood pressure in neonates and infants utilizing an automatic noninvasive oscillometric monitor.

R H Friesen, J L Lichtor.   

Abstract

An indirect automatic blood pressure (BP) monitor utilizing the oscillometric principle and a microprocessor is now available for use in infants. This device was evaluated by comparing its systolic BP determinations with simultaneous Doppler systolic BP determinations in neonates and infants undergoing general anesthesia. Five determinations each were made in 125 babies who were grouped according to age. Correlation coefficients of the paired BP determinations were: in 27 premature neonates, r = 0.82; in 24 term neonates, r = 0.93; in 47 infants aged 5 to 13 weeks, r = 0.92; and in 27 infants aged 14 to 26 weeks, r = 0.94. The device was also evaluated by comparing its BP determinations with those of indwelling arterial lines present in 20 additional infants (five determinations each). Correlation coefficients were 0.96 for systolic determinations and 0.94 for diastolic determinations. No morbidity or significant technical problems were noted. It was concluded that the device is an accurate, safe, and easy noninvasive method for monitoring BP in infants.

Entities:  

Mesh:

Year:  1981        PMID: 7197478

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  21 in total

1.  Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations.

Authors:  G P Gravlee; J K Brockschmidt
Journal:  J Clin Monit       Date:  1990-10

2.  Standard algorithm of blood-pressure measurement by the oscillometric method.

Authors:  A Sapiński
Journal:  Med Biol Eng Comput       Date:  1992-11       Impact factor: 2.602

3.  A quantitative evaluation of the Hewlett-Packard 78354A noninvasive blood pressure meter.

Authors:  P Whalen; A K Ream
Journal:  J Clin Monit       Date:  1988-01

4.  Accuracy of oscillometric blood pressure measurement in critically ill neonates with reference to the arterial pressure wave shape.

Authors:  M Gevers; H R van Genderingen; H N Lafeber; W W Hack
Journal:  Intensive Care Med       Date:  1996-03       Impact factor: 17.440

5.  The Dinamap 1846SX automated blood pressure recorder: comparison with the Hawksley random zero sphygmomanometer under field conditions.

Authors:  P H Whincup; N G Bruce; D G Cook; A G Shaper
Journal:  J Epidemiol Community Health       Date:  1992-04       Impact factor: 3.710

6.  Failure of autoregulation of cerebral blood flow in neonates studied by pulsed Doppler ultrasound of the internal carotid artery.

Authors:  G Jorch; N Jorch
Journal:  Eur J Pediatr       Date:  1987-09       Impact factor: 3.183

7.  Continuous wave Doppler velocimetry as an adjunct to cross sectional echocardiography in the diagnosis of critical left heart obstruction in neonates.

Authors:  P J Robinson; R K Wyse; J E Deanfield; R Franklin; F J Macartney
Journal:  Br Heart J       Date:  1984-11

8.  Clinical assessment of the neonatal Dinamap 847 during anesthesia in neonates and infants.

Authors:  P M Cullen; J Dye; D G Hughes
Journal:  J Clin Monit       Date:  1987-10

9.  Fundamentals of infant anaesthesia.

Authors:  C F Ward
Journal:  Can Anaesth Soc J       Date:  1984-05

10.  Dinamap fails to detect hypotension in very low birthweight infants.

Authors:  G K Diprose; D H Evans; L N Archer; M I Levene
Journal:  Arch Dis Child       Date:  1986-08       Impact factor: 3.791

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.