A quantitative evaluation of the Hewlett-Packard 78354A noninvasive blood pressure meter.

P Whalen1, A K Ream.   

Abstract

Oscillometrically determined brachial artery pressures were compared with simultaneous contralateral radial intraarterial pressures in 19 anesthetized adult cardiac surgical patients throughout their surgical procedures, interrupted only by nonpulsatile, low-pressure, low-flow cardiopulmonary bypass. Radial intraarterial pressure values ranged widely for systolic (55 to 207 torr), mean (43 to 141 torr), and diastolic (26 to 106 torr). Both error specification methods proposed by the Association for the Advancement of Medical Instrumentation were used and compared. As expected, error method 1 gave consistently lower mean errors, smaller error standard deviations, and higher correlation coefficients than did error method 2. The errors during time periods immediately before and after cardiopulmonary bypass were compared with those from more quiescent times. Higher mean errors, larger error standard deviations, and lower correlation and regression coefficients were found during those time periods surrounding cardiopulmonary bypass. In general, mean errors were lowest for systolic pressure, followed by mean and diastolic pressures in that order, whereas error standard deviations were smallest for mean pressure, followed by systolic and diastolic pressures. Correlation and regression coefficients were highest for systolic pressure, followed by mean and diastolic pressures. In summary, the oscillometric method provides convenient and reproducible estimates of radial intraarterial pressure during most clinical situations, typically with better accuracy than the auscultatory Korotkoff method. The accuracy and reproducibility are diminished during those periods immediately surrounding cardiopulmonary bypass, perhaps due to direct surgical manipulation of the heart with its attendant rapid changes in cardiac output and blood pressure.

Entities:  

Mesh:

Year:  1988        PMID: 3339388     DOI: 10.1007/bf01618104

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  15 in total

1.  The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure. 1.

Authors:  J A Posey; L A Geddes; H Williams; A G Moore
Journal:  Cardiovasc Res Cent Bull       Date:  1969 Jul-Sep

2.  A comparison of two automated indirect arterial blood pressure meters: with recordings from a radial arterial catheter in anesthetized surgical patients.

Authors:  E Nystrom; K H Reid; R Bennett; L Couture; H L Edmonds
Journal:  Anesthesiology       Date:  1985-04       Impact factor: 7.892

3.  Noninvasive automatic determination of mean arterial pressure.

Authors:  M Ramsey
Journal:  Med Biol Eng Comput       Date:  1979-01       Impact factor: 2.602

4.  Indirect measurement of blood pressure in neonates and infants utilizing an automatic noninvasive oscillometric monitor.

Authors:  R H Friesen; J L Lichtor
Journal:  Anesth Analg       Date:  1981-10       Impact factor: 5.108

5.  An assessment of the Dinamap 845.

Authors:  P Hutton; J Dye; C Prys-Roberts
Journal:  Anaesthesia       Date:  1984-03       Impact factor: 6.955

6.  Biases in the measurement of arterial pressure.

Authors:  K J Finnie; D G Watts; P W Armstrong
Journal:  Crit Care Med       Date:  1984-11       Impact factor: 7.598

7.  Hazard of automatic noninvasive blood pressure monitoring.

Authors:  A Showman; E K Betts
Journal:  Anesthesiology       Date:  1981-12       Impact factor: 7.892

8.  Recommendations for human blood pressure determination by sphygmomanometers. Subcommittee of the AHA Postgraduate Education Committee.

Authors:  W M Kirkendall; M Feinleib; E D Freis; A L Mark
Journal:  Circulation       Date:  1980-11       Impact factor: 29.690

9.  The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure--part ii.

Authors:  G W Mauck; C R Smith; L A Geddes; J D Bourland
Journal:  J Biomech Eng       Date:  1980-02       Impact factor: 2.097

10.  Comparison between oscillometric and invasive blood pressure monitoring during cardiac surgery.

Authors:  M Green; D A Paulus; V P Roan; J van der Aa
Journal:  Int J Clin Monit Comput       Date:  1984
View more
  3 in total

1.  Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations.

Authors:  G P Gravlee; J K Brockschmidt
Journal:  J Clin Monit       Date:  1990-10

2.  A Meta-analysis to Determine the Validity of Taking Blood Pressure Using the Indirect Cuff Method.

Authors:  Scott J Dankel; Minsoo Kang; Takashi Abe; Jeremy P Loenneke
Journal:  Curr Hypertens Rep       Date:  2019-02-07       Impact factor: 5.369

3.  Indirect blood pressure measurement using the Riva Rocci Korotkoff method.

Authors:  H H Ros
Journal:  J Clin Monit       Date:  1995-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.