Literature DB >> 7152801

Concepts for automatic perimetry, as applied to the Scoperimeter, an experimental automatic perimeter.

R W de Boer, T J van den Berg, E L Greve, B J de Waal.   

Abstract

The development of an experimental automatic perimeter, the Scoperimeter, is described. We use an oscilloscope as campimeter screen for the examination of the central 25 degrees of the visual field. The oscilloscope beam generates a homogeneous background luminance (0.1 cd/m2) and single stimulus static stimuli in any given position. The effective luminance-range of the stimuli is 3.0-3.5 log.unit. The visual field examination is controlled by a small computer system. Four examination programs written in Basic, are described. The screening programs using threshold related suprathreshold stimuli appear to be the most efficient compromise between speed and accuracy of the examination. The printout of these programs consists of a noninterpolated grey-scale presentation. Other programs perform static meridional perimetry or measure luminance threshold in 60 regularly distributed positions in the visual field. We have taken into consideration the factors that may influence the outcome of the examination: the presence of an instruction phase, the possibility to follow the progress of the examination and careful stimulus-timing. In a second paper we present clinical results we obtained using our instrument.

Entities:  

Mesh:

Year:  1982        PMID: 7152801     DOI: 10.1007/bf00149152

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  15 in total

1.  An automatic perimeter for glaucoma visual field screening and control. Construction and clinical cases.

Authors:  A Heijl; C E Krakau
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1975-10-17

2.  Static perimetry: strategies.

Authors:  H Bebie; F Fankhauser; J Spahr
Journal:  Acta Ophthalmol (Copenh)       Date:  1976-07

3.  Suprathreshold static perimetry. Initial clinical trials with the Fieldmaster automated perimeter.

Authors:  J L Keltner; C A Johnson; F G Balestrery
Journal:  Arch Ophthalmol       Date:  1979-02

4.  Single and multiple stimulus static perimetry in glaucoma; the two phases of perimetry. Thesis.

Authors:  E L Greve
Journal:  Doc Ophthalmol       Date:  1973-10-12       Impact factor: 2.379

5.  Computer test logics for automatic perimetry.

Authors:  A Heijl
Journal:  Acta Ophthalmol (Copenh)       Date:  1977-10

6.  [New programs for the Octopus automatic perimeter].

Authors:  A Jenni; F Fankhauser; H Bebie
Journal:  Klin Monbl Augenheilkd       Date:  1980-04       Impact factor: 0.700

7.  The fieldmaster 101 PR automatic visual field screener--technical evaluation and clinical results.

Authors:  R W de Boer; T J van den Berg; E L Greve; H J Bos
Journal:  Doc Ophthalmol       Date:  1982-12-01       Impact factor: 2.379

8.  The Ocuplot semi-automatic visual field screener--technical evaluation and clinical results.

Authors:  R W de Boer; T J van den Berg; E L Greve; L J de Heer; P Wiercx
Journal:  Doc Ophthalmol       Date:  1982-12-01       Impact factor: 2.379

9.  Automatic perimetry in glaucoma visual field screening. A clinical study.

Authors:  A Heijl
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1976-07-26

10.  Some aspects of the automation of perimetry.

Authors:  F Frankhauser; J Spahr; H Bebie
Journal:  Surv Ophthalmol       Date:  1977 Sep-Oct       Impact factor: 6.048

View more
  6 in total

1.  Results of a filtering procedure in low tension glaucoma.

Authors:  N de Jong; E L Greve; P F Hoyng; H C Geijssen
Journal:  Int Ophthalmol       Date:  1989-01       Impact factor: 2.031

2.  Clinical evaluation of the Scoperimeter, an experimental automatic perimeter.

Authors:  E L Greve; R W de Boer; D Bakker; J Moed
Journal:  Int Ophthalmol       Date:  1982-11       Impact factor: 2.031

3.  Performance of computer assisted perimeters.

Authors:  E L Greve
Journal:  Doc Ophthalmol       Date:  1982-12-01       Impact factor: 2.379

4.  The Peritest, a new automatic and semi-automatic perimeter.

Authors:  E L Greve; F Dannheim; D Bakker
Journal:  Int Ophthalmol       Date:  1982-11       Impact factor: 2.031

5.  Is there general reduction of sensitivity in glaucoma?

Authors:  C T Langerhorst; T J van den Berg; E L Greve
Journal:  Int Ophthalmol       Date:  1989-01       Impact factor: 2.031

6.  Comparison of Humphrey Field Analyzer and imo visual field test results in patients with glaucoma and pseudo-fixation loss.

Authors:  Hiroyasu Goukon; Kazunori Hirasawa; Masayuki Kasahara; Kazuhiro Matsumura; Nobuyuki Shoji
Journal:  PLoS One       Date:  2019-11-07       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.