Literature DB >> 7152803

The Peritest, a new automatic and semi-automatic perimeter.

E L Greve, F Dannheim, D Bakker.   

Abstract

The Peritest is a new automatic and semi-automatic (manual) perimeter for detection and limited assessment of visual field defects. It uses either multiple or single stimulus static perimetry. The lightsources are LED's. A total of 206 positions can be examined including the center; 151 positions inside 25 degrees-eccentricity. The programmes use a threshold-related gradient adapted suprathreshold (0.6) strategy. The results are printed on a special chart using non-interpolated grey scales for indicating local reduction of sensitivity. General and local reduction of sensitivity are separated. The progress of the examination can be followed on a LED-monitor. The reliability of the patient is measured. 70% of small early glaucomatous defects (that are only found by high resolution meridional static perimetry) were detected. Such defects are not usually detected by routine kinetic perimetry. More peripheral defects were detected (greater than 25 degrees) than by kinetic perimetry. Due to the relatively high number of stimuli the typical configuration of defects was satisfactorily demonstrated for defects of moderate size and larger. The duration of the examination varies from less than 4 min. for a semi-automatic examination of normal eyes to 10-20 min. for automatic examination of eyes with defects of moderate size (average 15 minutes for 206 positions).

Entities:  

Mesh:

Year:  1982        PMID: 7152803     DOI: 10.1007/bf00149155

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  6 in total

1.  Automation of perimetry.

Authors:  E L Greve; M T Groothuyse; W M Verduin
Journal:  Doc Ophthalmol       Date:  1976-03-31       Impact factor: 2.379

2.  Single and multiple stimulus static perimetry in glaucoma; the two phases of perimetry. Thesis.

Authors:  E L Greve
Journal:  Doc Ophthalmol       Date:  1973-10-12       Impact factor: 2.379

3.  Concepts for automatic perimetry, as applied to the Scoperimeter, an experimental automatic perimeter.

Authors:  R W de Boer; T J van den Berg; E L Greve; B J de Waal
Journal:  Int Ophthalmol       Date:  1982-11       Impact factor: 2.031

4.  Clinical evaluation of the Scoperimeter, an experimental automatic perimeter.

Authors:  E L Greve; R W de Boer; D Bakker; J Moed
Journal:  Int Ophthalmol       Date:  1982-11       Impact factor: 2.031

5.  The fieldmaster 101 PR automatic visual field screener--technical evaluation and clinical results.

Authors:  R W de Boer; T J van den Berg; E L Greve; H J Bos
Journal:  Doc Ophthalmol       Date:  1982-12-01       Impact factor: 2.379

6.  Performance of computer assisted perimeters.

Authors:  E L Greve
Journal:  Doc Ophthalmol       Date:  1982-12-01       Impact factor: 2.379

  6 in total
  7 in total

1.  Scanning laser densitometry in visual acuity loss of unknown origin.

Authors:  P J DeLint; J E Keunen; A T Liem; D van Norren
Journal:  Br J Ophthalmol       Date:  1996-12       Impact factor: 4.638

2.  Concepts for automatic perimetry, as applied to the Scoperimeter, an experimental automatic perimeter.

Authors:  R W de Boer; T J van den Berg; E L Greve; B J de Waal
Journal:  Int Ophthalmol       Date:  1982-11       Impact factor: 2.031

3.  Clinical evaluation of the Scoperimeter, an experimental automatic perimeter.

Authors:  E L Greve; R W de Boer; D Bakker; J Moed
Journal:  Int Ophthalmol       Date:  1982-11       Impact factor: 2.031

4.  Ophthalmological Findings in Youths With a Newly Diagnosed Brain Tumor.

Authors:  Myrthe A Nuijts; Inge Stegeman; Tom van Seeters; Marloes D Borst; Carlien A M Bennebroek; Dennis R Buis; Nicole C Naus; Giorgio L Porro; Michelle B van Egmond-Ebbeling; Elisabeth S M Voskuil-Kerkhof; JanWillem R Pott; Niels E Franke; Evelien de Vos-Kerkhof; Eelco W Hoving; Antoinette Y N Schouten-van Meeteren; Saskia M Imhof
Journal:  JAMA Ophthalmol       Date:  2022-10-01       Impact factor: 8.253

5.  Performance of computer assisted perimeters.

Authors:  E L Greve
Journal:  Doc Ophthalmol       Date:  1982-12-01       Impact factor: 2.379

6.  Visual impairment in children with a brain tumor: a prospective nationwide multicenter study using standard visual testing and optical coherence tomography (CCISS study).

Authors:  M A Nuijts; M H Degeling; I Stegeman; A Y N Schouten-van Meeteren; S M Imhof
Journal:  BMC Ophthalmol       Date:  2019-11-09       Impact factor: 2.209

7.  Ophthalmological Evaluation in Children Presenting With a Primary Brain Tumor.

Authors:  Myrthe A Nuijts; Inge Stegeman; Giorgio L Porro; Josje C Duvekot; Michelle B van Egmond-Ebbeling; Denise C P van der Linden; Eelco W Hoving; Antoinette Y N Schouten-van Meeteren; Saskia M Imhof
Journal:  J Neuroophthalmol       Date:  2021-10-29       Impact factor: 4.415

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.