Literature DB >> 7140317

Can central venous blood replace mixed venous blood samples?

J Tahvanainen, O Meretoja, P Nikki.   

Abstract

To estimate the value of central venous blood as representative of real changes in pulmonary shunt (Qsp/Qt), mixed venous oxygen saturation and arteriovenous oxygen content difference [C(a-v)O2] during active phases of adult intensive care therapy, 86 blood samples were withdrawn from 42 patients as quadruple simultaneous collections from systemic artery, pulmonary artery (PA), superior caval vein (CV) and right atrium (RA). We found a significant positive correlation of the measured variables and especially of the subsequent changes of these variables in individual patients between PA blood samples and both CV and RA blood samples (p less than 0.001). We, therefore, conclude that a central venous catheter can replace the PA catheter to collect blood representative of mixed venous blood samples for the above purposes. However, the exact numerical value of mixed venous blood samples can only be measured from blood collected from the PA itself.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7140317     DOI: 10.1097/00003246-198211000-00012

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  19 in total

1.  Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock.

Authors:  Marjut Varpula; Sari Karlsson; Esko Ruokonen; Ville Pettilä
Journal:  Intensive Care Med       Date:  2006-07-07       Impact factor: 17.440

2.  Evaluation of a computer program for non-invasive determination of pulmonary shunt and ventilation-perfusion mismatch.

Authors:  Geoffrey G Lockwood; Nick L S Fung; J Gareth Jones
Journal:  J Clin Monit Comput       Date:  2014-01-09       Impact factor: 2.502

3.  Comparison of a modified Fick method with thermodilution for determining cardiac output in critically ill patients on mechanical ventilation.

Authors:  J Lynch; H Kaemmerer
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

4.  Continuous central venous oxygen saturation (ScvO2) measurement using a fibre optic catheter in newborn infants.

Authors:  M A van der Hoeven; W J Maertzdorf; C E Blanco
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-05       Impact factor: 5.747

5.  Central venous oxygen saturation accurately reflects mixed venous oxygen saturation during laparotomy.

Authors:  Masayasu Nakayama; Noriaki Kanaya; Hideaki Tsuchida; Akiyoshi Namiki
Journal:  J Anesth       Date:  1996-12       Impact factor: 2.078

6.  Respiratory function and carbonic anhydrase inhibition.

Authors:  P G Berthelsen; J O Dich-Nielsen
Journal:  Intensive Care Med       Date:  1987       Impact factor: 17.440

7.  Measurement of right atrial oxygen saturation by fiberoptic oximetry accurately reflects mixed venous oxygen saturation in swine.

Authors:  G G Davies; J Mendenhall; T Symreng
Journal:  J Clin Monit       Date:  1988-04

8.  Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill.

Authors:  Konrad Reinhart; Hans-Jörg Kuhn; Christiane Hartog; Donald L Bredle
Journal:  Intensive Care Med       Date:  2004-06-09       Impact factor: 17.440

9.  [Noninvasive determination of cardiac output in ventilated patients . Clinical evaluation of a simplified quick method].

Authors:  J Reutershan; T Kapp; K Unertl; R Fretschner
Journal:  Anaesthesist       Date:  2003-09       Impact factor: 1.041

10.  Superior vena caval and mixed venous oxyhemoglobin saturations in children recovering from open heart surgery.

Authors:  J Räsänen; K Peltola; M Leijala
Journal:  J Clin Monit       Date:  1992-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.