Abstract

The special conditions contributing to the loosening of 61 hip prostheses were studied and compared with 325 clinical and roentgenologically intact total hip replacements. The loosening rate rose sharply after the 6th postoperative year. One third of the artificial joints examined showed signs of loosening after the 9th year. The average loosening rate was 15.8% after 5.8 years. The condition of the bony bed apparently plays an important role, both qualitatively and quantitatively, in the success of the implant. The operative procedure is of equal importance. Deep fraising of the acetabulum, removal of insufficient amounts of cancellous bone from the proximal femur and inadequate embedding of the prosthesis stem, implantation of the stem in varus, and the use of long-neck femoral head prostheses are all factors which increase the risk of loosening. Ultimately, it is the sum of these loosening factors including the biological reaction of the tissue to the biomechanical and biochemically active foreign body which, depending on the period of influence, leads to prosthesis loosening. It is imperative that the patient's lifestyle be adjusted accordingly since external weight-bearing stress also affects durability of the prosthesis.

Entities:  

Mesh:

Year:  1982        PMID: 7125870     DOI: 10.1007/bf00381538

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  19 in total

1.  [Bone stress and reconstruction of the bone at the alloarthroplasty of the upper end of the femur with cement bonding (author's transl)].

Authors:  K Diehl
Journal:  Arch Orthop Unfallchir       Date:  1975-09-04

2.  [First experiences with a cementlen isoelastic total hip prosthesis].

Authors:  E Morscher; R Mathys
Journal:  Z Orthop Ihre Grenzgeb       Date:  1975-08

3.  [Complications after total hip replacement (author's transl)].

Authors:  K P Schulitz; H O Dustmann
Journal:  Arch Orthop Unfallchir       Date:  1976-06-18

4.  [Contraindications for total hip prosthesis (author's transl)].

Authors:  W D Schellmann; H Erdmann; K Klemm
Journal:  Arch Orthop Unfallchir       Date:  1974

5.  [Losening of acetabular prosthesis with various methods of implantation used in cadaver-hipjoints (author's transl)].

Authors:  M Jäger; W Küsswetter; J Rütt; M Ungethüm; R Burkhardt
Journal:  Z Orthop Ihre Grenzgeb       Date:  1974-02

6.  [Biomechanical caused of loosening and breaking of the hip joint prothesess (author's transl)].

Authors:  G Ritter; A Grünert; C H Schweikert
Journal:  Arch Orthop Unfallchir       Date:  1973-11-13

7.  [The problem of acetabular loosening in patients with total hip joint replacement (author's transl)].

Authors:  K H Täger
Journal:  Arch Orthop Unfallchir       Date:  1977-01-21

8.  Total hip arthroplasty: a review of four years experience.

Authors:  E T Preston
Journal:  Clin Orthop Relat Res       Date:  1978 Nov-Dec       Impact factor: 4.176

9.  Total hip replacement by the Müller-Charnley prosthesis. A follow-up study of 238 operations after 2 to 7 years.

Authors:  S S Olsson; A Jernberger; D Tryggö
Journal:  Acta Orthop Scand       Date:  1979-08

10.  [Further experiences with total hip arthroplasty. Clinical and roentgenographic results after 3--6 years following implantation (author's transl)].

Authors:  M H Hackenbroch; H Bruns; R Holbe; H Lechleuthner
Journal:  Arch Orthop Unfallchir       Date:  1976-03-26
View more
  5 in total

1.  Aseptic loosening of straight- and curved-stem Müller femoral prostheses.

Authors:  M Krismer; M Klar; T Klestil; B Frischhut
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

2.  Uncoated polyethylene RM acetabular component versus Müller cemented acetabular component. A 4- to 8-year follow-up study.

Authors:  M Krismer; M Fischer; T Klestil; B Frischhut
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

3.  Computer-aided manufacture of individual endoprostheses. Preliminary communication.

Authors:  G Aldinger; A Fischer; B Kurtz
Journal:  Arch Orthop Trauma Surg       Date:  1983

4.  Rare fracture of a total hip replacement.

Authors:  G Aldinger; K Mitzkat
Journal:  Arch Orthop Trauma Surg       Date:  1983

5.  Morphological investigations of a porous aluminum oxide ceramic and the consequences for clinical application.

Authors:  M Forgon; E Mammel; K Trombitás; L Kacsalova; I Dráveczki
Journal:  Arch Orthop Trauma Surg       Date:  1987
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.