Aseptic loosening of straight- and curved-stem Müller femoral prostheses.

M Krismer1, M Klar, T Klestil, B Frischhut.   

Abstract

Out of 1099 Müller total hip prostheses with straight and curved stems consecutively implanted between 1980 and 1984, those performed in as homogeneous a group as possible of patients under the age of 70 years were selected for the present retrospective study. There were 158 straight femoral stems with cementless RM acetabular cups, 105 straight stems with cemented Müller acetabular cups, and 158 curved stems with cemented Müller acetabular cups, and their results over a mean follow-up period of 5.8 +/- 1.24 years were compared. Six (3.7%) curved and 5 (1.9%) straight-stem prostheses were exchanged due to aseptic loosening; 26 (16.3%) curved and 54 (20.1%) straight-stem prostheses were "at risk" or loose at the time of follow-up. Survival curves show a worse result for straight stems after 6 years; within a follow-up period of 6-8 years there was significantly more radiological loosening in straight stems than in curved. Loosening in straight stems is assumed to develop mainly as a physiological reaction to the presence of bone cement particles.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1892713     DOI: 10.1007/bf00571057

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  13 in total

1.  Comparison between straight- and curved-stem Müller femoral prostheses. 5- to 10-year results of 545 total hip replacements.

Authors:  J Wilson-MacDonald; E Morscher
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067

2.  The validity of survivorship analysis in total joint arthroplasty.

Authors:  F Dorey; H C Amstutz
Journal:  J Bone Joint Surg Am       Date:  1989-04       Impact factor: 5.284

3.  [Numerical evaluation of hip function].

Authors:  R Merle D'Augibné
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1970 Jul-Aug

4.  A radiographic analysis of 166 Charnley-Müller total hip arthroplasties.

Authors:  P Cotterill; G A Hunter; M Tile
Journal:  Clin Orthop Relat Res       Date:  1982-03       Impact factor: 4.176

5.  Proximal strain distribution in the loaded femur. An in vitro comparison of the distributions in the intact femur and after insertion of different hip-replacement femoral components.

Authors:  I Oh; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1978-01       Impact factor: 5.284

6.  Clinical and radiological long-term results after Charnley-Müller total hip replacement. A 5 to 10 year follow-up study with special reference to aseptic loosening.

Authors:  S S Olsson; A Jernberger; D Tryggö
Journal:  Acta Orthop Scand       Date:  1981-10

7.  Aseptic loosening of cement-anchored total hip replacements.

Authors:  G Aldinger; J Gekeler
Journal:  Arch Orthop Trauma Surg       Date:  1982

8.  Ten-year follow-up of Müller hip replacements.

Authors:  O Reikerås
Journal:  Acta Orthop Scand       Date:  1982-12

9.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

10.  Intermediate results of a straight stem prosthesis in primary total hip arthroplasty.

Authors:  S B Goodman; J Schatzker
Journal:  Clin Orthop Relat Res       Date:  1987-05       Impact factor: 4.176

View more
  4 in total

1.  Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients.

Authors:  Hao Tang; Dejin Yang; Shengjie Guo; Jing Tang; Jian Liu; Dacheng Wang; Yixin Zhou
Journal:  Skeletal Radiol       Date:  2016-09-02       Impact factor: 2.199

2.  Subsidence of titanium straight stems in combination with highly viscous bone cement.

Authors:  Christian Hendrich; Ulf Sauer; Tobias Albrecht; Christof P Rader
Journal:  Int Orthop       Date:  2005-02-10       Impact factor: 3.075

3.  The posterior approach reduces the risk of thin cement mantles with a straight femoral stem design.

Authors:  Gavin J Macpherson; Christian Hank; Michael Schneider; Morag Trayner; Robert Elton; Colin R Howie; Steffen J Breusch
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

4.  Cemented Müller straight stem total hip replacement: 18 year survival, clinical and radiological outcomes.

Authors:  Vasileios S Nikolaou; Demetrios Korres; Stergios Lallos; Andreas Mavrogenis; Ioannis Lazarettos; Ioannis Sourlas; Nicolas Efstathopoulos
Journal:  World J Orthop       Date:  2013-10-18
  4 in total