Literature DB >> 7110074

A solid water phantom material for radiotherapy x-ray and gamma-ray beam calibrations.

C Constantinou, F H Attix, B R Paliwal.   

Abstract

The formulation, manufacture and testing of an epoxy resin-based solid substitute for water is presented. This "solid water" has radiation characteristics very close volumetrically to those of water. When it is used as a dosimetry phantom for x- and gamma-ray beams in the radiotherapy range, phantom-to-water corrections and density corrections are eliminated. Relative transmission measurements have shown that the transmission through 10 cm of solid water is within 0.2% of that through an equal thickness of water for x and gamma rays. The use of this material for calibration phantoms can help achieve the goal of radiotherapy beam calibrations within +/- 1.0% of the true dose rate, easier to achieve.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7110074     DOI: 10.1118/1.595063

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Direct action of radiation on mummified cells: modeling of computed tomography by Monte Carlo algorithms.

Authors:  Johann Wanek; Robert Speller; Frank Jakobus Rühli
Journal:  Radiat Environ Biophys       Date:  2013-04-25       Impact factor: 1.925

Review 2.  Evolution of radiation protection for medical workers.

Authors:  John Boice; Lawrence T Dauer; Kenneth R Kase; Fred A Mettler; Richard J Vetter
Journal:  Br J Radiol       Date:  2020-06-04       Impact factor: 3.039

3.  A reproducible radiation delivery method for unanesthetized rodents during periods of hind limb unloading.

Authors:  M C Walb; P J Black; V S Payne; M T Munley; J S Willey
Journal:  Life Sci Space Res (Amst)       Date:  2015-07

4.  Design, Fabrication, and Validation of a Polymethyl Methacrylate Head Phantom for Dosimetric Verification of Cranial Radiotherapy Treatment Plans.

Authors:  V S Shaiju; Rajesh Kumar; Debjani Phani; K V Rajasekhar; George Zacharia; Saju Bhasi; Raghuram K Nair
Journal:  J Med Phys       Date:  2020-07-20

5.  X-ray phase contrast imaging of the breast: analysis of tissue simulating materials.

Authors:  Srinivasan Vedantham; Andrew Karellas
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

6.  Beta-particle dosimetry in radiation synovectomy.

Authors:  L S Johnson; J C Yanch; S Shortkroff; C L Barnes; A I Spitzer; C B Sledge
Journal:  Eur J Nucl Med       Date:  1995-09

7.  Monte Carlo-based investigation of water-equivalence of solid phantoms at (137)Cs energy.

Authors:  Ramkrushna S Vishwakarma; T Palani Selvam; Sridhar Sahoo; Subhalaxmi Mishra; Ghanshyam Chourasiya
Journal:  J Med Phys       Date:  2013-10

8.  Dosimetric impact of density variations in Solid Water 457 water-equivalent slabs.

Authors:  Dale W Litzenberg; Hanan Amro; Joann I Prisciandaro; Eduardo Acosta; Ian Gallagher; Don A Roberts
Journal:  J Appl Clin Med Phys       Date:  2011-04-22       Impact factor: 2.102

9.  Solid water phantom heat conduction: Heating and cooling rates.

Authors:  Martin J Butson; Tsang Cheung; Peter K N Yu
Journal:  J Med Phys       Date:  2008-01

10.  Dosimetric evaluation of Plastic Water Diagnostic-Therapy.

Authors:  Ramani Ramaseshan; Kirpal Kohli; Fred Cao; Robert K Heaton
Journal:  J Appl Clin Med Phys       Date:  2008-04-29       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.