Literature DB >> 7060059

Measurement of instantaneous blood-flow velocity in the human aorta using pulsed Doppler ultrasound.

S E Gisvold, A O Brubakk.   

Abstract

The reproducibility and ease of use of a pulsed Doppler system has been investigated in 27 normal subjects. Measurements were performed in the ascending aorta and the aortic arch in the sitting and supine position. Good quality recordings were obtained in over 90% of the subjects. Maximum velocities of 120 and 108 cm . s-1 were found in the supine position of the ascending aorta in males and females respectively, while the corresponding acceleration were 2254 and 2148 cm . s-2. When moving from the sitting to the supine position, changes in integral under the mean and maximum velocity curve, which is supposed to be proportioned to stroke volume, were approximately 30% both in the ascending aorta and in the aorta arch. Making certain assumptions about dimensions of the aorta, reasonable values for cardiac output could be calculated in all subjects. The reproducibility of the measurements was tested by making ten repeat measurements in five subjects. The mean variation coefficient was between 6 and 11% for all measured variables. It is concluded that blood-flow velocity can be measured in the ascending aorta and the aortic arch using pulsed ultrasound and that the method has a reproducibility which permits measurements of changes in the flow and flow velocity of over 10%.

Entities:  

Mesh:

Year:  1982        PMID: 7060059     DOI: 10.1093/cvr/16.1.26

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  13 in total

1.  Reproducibility of Doppler blood flow velocity waveform measurements: study on variability within and between day and during haemodynamic intervention in normal subjects.

Authors:  G H Rimoy; N K Bhaskar; P C Rubin
Journal:  Eur J Clin Pharmacol       Date:  1991       Impact factor: 2.953

2.  Functional asymmetry in carotid sinus cardiac reflexes in humans.

Authors:  M Tafil-Klawe; F Raschke; G Hildebrandt
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1990

3.  Pharmacodynamic monitoring during acute intervention in ischaemic heart disease using a new echo-Doppler device.

Authors:  B Silke; S P Verma; S H Taylor
Journal:  Br J Clin Pharmacol       Date:  1990-06       Impact factor: 4.335

4.  Investigations of renal artery blood flow velocity in preterm and term neonates by pulsed Doppler ultrasonography.

Authors:  T Bömelburg; G Jorch
Journal:  Eur J Pediatr       Date:  1988-04       Impact factor: 3.183

5.  Doppler-derived cardiac output in healthy newborn infants in relation to physiological patency of the ductus arteriosus.

Authors:  H Hirsimäki; P Kero; O Wanne; R Erkkola; Z Makoi
Journal:  Pediatr Cardiol       Date:  1988       Impact factor: 1.655

6.  Reproducibility of linear cardiac output measurement by Doppler ultrasound alone.

Authors:  F M McLennan; N E Haites; J D Mackenzie; M K Daniel; J M Rawles
Journal:  Br Heart J       Date:  1986-01

7.  Flow Dynamics in the Aortic Arch and Its Effect on the Arterial Input Function in Cardiac Computed Tomography.

Authors:  Parastou Eslami; Jung-Hee Seo; Albert C Lardo; Marcus Y Chen; Rajat Mittal
Journal:  J Biomech Eng       Date:  2019-03-06       Impact factor: 2.097

8.  Mean or maximum velocity using pulsed Doppler ultrasound in determination of Doppler-derived cardiac output in the newborn infant.

Authors:  H Hirsimäki; P Kero; T Seppälä; K Holmström
Journal:  Med Biol Eng Comput       Date:  1993-01       Impact factor: 2.602

Review 9.  Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part II: Novel techniques and new advances.

Authors:  D E Warburton; M J Haykowsky; H A Quinney; D P Humen; K K Teo
Journal:  Sports Med       Date:  1999-04       Impact factor: 11.136

10.  Cardiac function in healthy infants and children: Doppler echocardiographic evaluation.

Authors:  K Hanseus; G Björkhem; N R Lundström
Journal:  Pediatr Cardiol       Date:  1994 Sep-Oct       Impact factor: 1.655

View more