Literature DB >> 30840028

Flow Dynamics in the Aortic Arch and Its Effect on the Arterial Input Function in Cardiac Computed Tomography.

Parastou Eslami1, Jung-Hee Seo2, Albert C Lardo3, Marcus Y Chen4, Rajat Mittal5.   

Abstract

The arterial input function (AIF)-time-density curve (TDC) of contrast at the coronary ostia-plays a central role in contrast enhanced computed tomography angiography (CTA). This study employs computational modeling in a patient-specific aorta to investigate mixing and dispersion of contrast in the aortic arch (AA) and to compare the TDCs in the coronary ostium and the descending aorta. Here, we examine the validity of the use of TDC in the descending aorta as a surrogate for the AIF. Computational fluid dynamics was used to study hemodynamics and contrast dispersion in a CTA-based patient model of the aorta. Variations in TDC between the aortic root, through the AA and at the descending aorta and the effect of flow patterns on contrast dispersion was studied via post-processing of the results. Simulations showed complex unsteady patterns of contrast mixing and dispersion in the AA that are driven by the pulsatile flow. However, despite the relatively long intra-aortic distance between the coronary ostia and the descending aorta, the TDCs at these two locations were similar in terms of rise-time and up-slope, and the time lag between the two TDCs was 0.19 seconds. TDC in the descending aorta is an accurate analog of the AIF. Methods that use quantitative metrics such as rise-time and slope of the AIF to estimate coronary flowrate and myocardial ischemia can continue with the current practice of using the TDC at the descending aorta as a surrogate for the AIF.

Entities:  

Year:  2019        PMID: 30840028      PMCID: PMC6808008          DOI: 10.1115/1.4043076

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  26 in total

1.  SCCT guidelines for performance of coronary computed tomographic angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee.

Authors:  Suhny Abbara; Armin Arbab-Zadeh; Tracy Q Callister; Milind Y Desai; Wilfred Mamuya; Louise Thomson; Wm Guy Weigold
Journal:  J Cardiovasc Comput Tomogr       Date:  2009-03-31

2.  Computational Study of Computed Tomography Contrast Gradients in Models of Stenosed Coronary Arteries.

Authors:  Parastou Eslami; Jung-Hee Seo; Amir Ali Rahsepar; Richard George; Albert C Lardo; Rajat Mittal
Journal:  J Biomech Eng       Date:  2015-07-09       Impact factor: 2.097

3.  A Computational Method for Analyzing the Biomechanics of Arterial Bruits.

Authors:  Chi Zhu; Jung-Hee Seo; Hani Bakhshaee; Rajat Mittal
Journal:  J Biomech Eng       Date:  2017-05-01       Impact factor: 2.097

4.  Aortic valve leaflet motion during systole. Numerical-graphical determination.

Authors:  W M Swanson; R E Clark
Journal:  Circ Res       Date:  1973-01       Impact factor: 17.367

5.  Time of flight quantification of coronary flow with echo-planar MRI.

Authors:  B P Poncelet; R M Weisskoff; V J Wedeen; T J Brady; H Kantor
Journal:  Magn Reson Med       Date:  1993-10       Impact factor: 4.668

6.  Three-dimensional coupled fluid-structure simulation of pericardial bioprosthetic aortic valve function.

Authors:  V B Makhijani; H Q Yang; P J Dionne; M J Thubrikar
Journal:  ASAIO J       Date:  1997 Sep-Oct       Impact factor: 2.872

7.  Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study.

Authors:  W Bob Meijboom; Matthijs F L Meijs; Joanne D Schuijf; Maarten J Cramer; Nico R Mollet; Carlos A G van Mieghem; Koen Nieman; Jacob M van Werkhoven; Gabija Pundziute; Annick C Weustink; Alexander M de Vos; Francesca Pugliese; Benno Rensing; J Wouter Jukema; Jeroen J Bax; Mathias Prokop; Pieter A Doevendans; Myriam G M Hunink; Gabriel P Krestin; Pim J de Feyter
Journal:  J Am Coll Cardiol       Date:  2008-12-16       Impact factor: 24.094

8.  Blood flow analysis of the aortic arch using computational fluid dynamics.

Authors:  Satoshi Numata; Keiichi Itatani; Keiichi Kanda; Kiyoshi Doi; Sachiko Yamazaki; Kazuki Morimoto; Kaichiro Manabe; Koki Ikemoto; Hitoshi Yaku
Journal:  Eur J Cardiothorac Surg       Date:  2016-01-20       Impact factor: 4.191

9.  Diagnostic performance of coronary angiography by 64-row CT.

Authors:  Julie M Miller; Carlos E Rochitte; Marc Dewey; Armin Arbab-Zadeh; Hiroyuki Niinuma; Ilan Gottlieb; Narinder Paul; Melvin E Clouse; Edward P Shapiro; John Hoe; Albert C Lardo; David E Bush; Albert de Roos; Christopher Cox; Jeffery Brinker; João A C Lima
Journal:  N Engl J Med       Date:  2008-11-27       Impact factor: 91.245

10.  Age-Related Vascular Changes Affect Turbulence in Aortic Blood Flow.

Authors:  Hojin Ha; Magnus Ziegler; Martin Welander; Niclas Bjarnegård; Carl-Johan Carlhäll; Marcus Lindenberger; Toste Länne; Tino Ebbers; Petter Dyverfeldt
Journal:  Front Physiol       Date:  2018-01-25       Impact factor: 4.566

View more
  2 in total

1.  Geometric Analysis of Type B Aortic Dissections Shows Aortic Remodeling After Intervention Using Multilayer Stents.

Authors:  Victor S Costache; Jorn P Meekel; Andreea Costache; Tatiana Melnic; Crina Solomon; Anca M Chitic; Cristian Bucurenciu; Horatiu Moldovan; Iulian Antoniac; Gabriela Candea; Kak K Yeung
Journal:  Materials (Basel)       Date:  2020-05-15       Impact factor: 3.623

2.  Calciprotein Particles Cause Endothelial Dysfunction under Flow.

Authors:  Daria Shishkova; Victoria Markova; Maxim Sinitsky; Anna Tsepokina; Elena Velikanova; Leo Bogdanov; Tatiana Glushkova; Anton Kutikhin
Journal:  Int J Mol Sci       Date:  2020-11-20       Impact factor: 5.923

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.